Abstract
To assess the left ventricular (LV) performance more sensitively, a new display method of phase plane (PP), displaying volume and volume-time function (dV/dt) in a single image, was applied to radionuclide ventriculography obtained by a single cardiac probe system. The sampling interval was 10 msec and the data acquisition time was 60 sec. The LV volume curve was smoothed by fitting a fourth order polynomial curve of Fourier’s analysis. Then the dV/dt was calculated. In this single image PP display, the width of the horizontal axis indicates relative LV volume, and the height of the vertical axis indicates dV/dt. The direction of the rotation of this loop is clockwise. We classified 126 patients with various heart diseases into seven groups, according to the configuration of the loop. The most interesting finding was that the distortion of the loop during diastole was frequently seen in patients with hypertension and angina pectoris, whereas their ejection fraction was within normal limits. We concluded that the single image PP display is a sensitive method for assessing the abnormality of the LV function, not only by evaluating the conventional parameters, but also by analyzing the configuration of the volume to volume-time function loop.
Similar content being viewed by others
References
Strauss HW, Pitt B: Gated blood pool imaging. In Cardiovascular Nuclear Medicine, 2nd Ed., Strauss HW and Pitt B ed., Mosby, St. Louis, pp 126–147, 1979
Strauss HW, Boucher CA: Radionuclide Angiography.Am J Cardiol 49: 1337, 1982
Borer JS, Bacharach SL, Green MV, et al: Assessment of ventricular function by radionuclide angiography: applications and results.Cardiology 71: 136, 1984
Ide M, Kanemoto N, Goto Y, et al: OMINISCOPE—A computerized cardiac single praobe system combined with B-mode ultrasound instrument.Kokyu to Junkan 32: 1039, 1984
Ide M, Kanemoto N, Goto Y, et al: Evaluation of left ventricular functions using a cadmium telluride probe.Jpn J Nucl Med 23: 1675, 1986
Nakamura M, Suzuki Y, Tomoda H: A quantitative approach for correction of background counts: Determination of left ventricular ejection fraction by radionuclide angiocardiography.IEEE Trans Bio Med Vol BME 29: 523, 1982
Suzuki Y, Nakamura M, Tomoda H, et al: Microcomputerbased scintillation prode system for assessment of left ventricular ejection fraction.Jpn J Nucl Med 20: 1183, 1983
Suzuki Y, Ono Y, Kinoshita E, et al: Estimation of left ventricular ejection fraction by computerized single cardiac parobe system.Jpn J Nucl Med 21: 353, 1984
Hammermeister KE, Warbasse JR: The rate of change of left ventricular volume in man. 2. Diastolic events in health and disease.Circulation 49: 739, 1974
Tomoda H, Matsuyama S: Left ventricular diastolic properties in man with special reference to the early diastolic period.Jpn J Nucl Med 17: 124, 1978
Watanabe S, Yasue T, Akabane H, et al: RV function evaluation using volume-pressure loop by ECG-gated equilibrium radionuclide angiography and simultaneously acquired RV pressure data.Jpn J Nucl Med 18: 75, 1981
Tamaki N, Kodama S, Yonekura Y, et al: Analysis of left ventricular global and regional functions in coronary artery disease by multigated forward and backward data collection.Jpn J Nucl Med 22: 147, 1985
Furutani Y, Ozaki M, Ikezono T, et al: Analysis of left ventricular systolic, diastolic properties, and left atrial contraction during acute increase in afterload in normal subjects: Assessment with forward and backward gating radionuclide ventriculography.Jpn J Nucl Med 23: 213, 1986
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ide, M., Suzuki, Y., Hirose, S. et al. Phase plane (volume to volume-time function loop) display of data from radionuclide ventriculography obtained by single cardiac probe system. Ann Nucl Med 2, 95–100 (1988). https://doi.org/10.1007/BF03164952
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03164952