Abstract
An experimental study with phantoms was performed in order to evaluate the effect of the tumor volume on the quantitative estimation in tumor SPECT. The ratio of mean count/pixel in the phantom to that of the background (T/N ratio) was well correlated with the size of the phantom: even when the concentration of the Tc-99m O4 - solution of globular phantoms with diameters of 29, 37 and 46 mm was constant, the greater the size of the phantom, the higher was the T/N ratio. This study showed that we should understand that the T/N ratio was certainly affected by the reduction of the tumor size itself whenever we evaluate treatment response or assess tumor viability after treatment by reference to the T/N ratio.
Similar content being viewed by others
References
Kaplan WD, Takvorian T, Morris JH, Rumbaugh CL, Conolly BT. Thallium-201 brain tumor imaging: A comparative study with pathologic correlation.J Nucl Med 28: 47–52, 1987.
Kim KT, Black KL, Marciano D, Mazziotta JC, Guze BH, Grafton S, et al. Thallium-201 SPECT imaging of brain tumors: Methods and Results.J Nucl Med 31: 965–969, 1990.
Togawa T, Yui N, Kinoshita F, Yanagisawa M, Namba H. A study on thallium-201 SPECT in brain metastases of lung cancer: with special reference to tumor size and tumor to normal brain thallium uptake ratio.KAKU IGAKU (Jpn J Nucl Med) 32: 217–225, 1995.
Black KL, Hawkins RA, Kim KT, Becker DP, Lerner C, Marciano D. Use of thallium-201 SPECT to quantitate malignacy grade of gliomas.J Neurosurg 71: 342–346, 1989.
Lin J, Leung W, Ho SKW, Ho KC, Kumta SM, Metreweli C, et al. Quantitative evaluation of thallium-201 uptake in predicting chemotherapeutic response of osteosarcoma.Eur J Nucl Med 22: 553–555, 1995.
Clarke LP, Leong LL, Serafin AN, Tyson IB, Silbiger ML. Quantitative SPECT imaging: influence of object size.Nucl Med Commun 7: 363–372, 1986.
Israel O, Front D, Lam M, Ben-haim S, Kleinhaus U, Benshachar M, et al. Gallium-67 imaging in monitoring lymphoma response to treatment.Cancer 61: 2439–2441, 1988.
Tomura N, Kobayashi M, Oyama Y, Satoh K, Kato K, Kusaka K, et al. Thallium-201 single photon emission computed tomography in the evaluation of therapeutic response for brain tumors.KAKU IGAKU (Jpn J Nucl Med) 31: 951–956, 1994.
Nakajima K, Hisada K, Iida H, Seki H, Muramori A. Detectability of small hot lesions in single photon emission computed tomography: Experiments using phantom and computer simulation.KAKU IGAKU (Jpn J Nucl Med) 24: 397–405, 1987.
Higashi T, Wakao H, Nakamura A. Quantitative Ga-67 scanning for predicting value in primary lung carcinoma.J Nucl Med 21: 628–632, 1980.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Togawa, T., Yui, N., Kinoshita, F. et al. Quantitative evaluation in tumor SPECT and the effect of tumor size: Fundamental study with phantom. Ann Nucl Med 11, 51–54 (1997). https://doi.org/10.1007/BF03164760
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03164760