Abstract
Expressions have been obtained for the Geometrical Sensitivity as a function of the zenith angle of a cosmic ray telescope comprising of counter trays of rectangular dimensions. The Radiation Sensitivity and Cumulative Sensitivity have also been calculated, assuming a zenith angle attenuation of the form Iθ=Iθ.cos2θ for cosmic ray intensity.
Similar content being viewed by others
References
Greisen, K. and Nereson, N.Phys. Rev., 1942,62, 316.
Parsons, N. R.Rev. Sci. Instru., 1957,28, 265.
Author information
Authors and Affiliations
Additional information
Communicated by Prof. V. A. Sarabhai,f.a.sc.
Rights and permissions
About this article
Cite this article
Kane, R.P., Rao, U.R. Zenith angle response of a vertical meson telescope. Proc. Indian Acad. Sci. 47, 30–40 (1958). https://doi.org/10.1007/BF03052623
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF03052623