Abstract

The main payload on CBERS-01/02 of China-Brazil Earth Resources Satellite (CBERS) is a push-broom CCD camera with moderate spatial and radiant resolution. Because at lab the data for calibration at satellite assembly stage were unable to be collected, and also because the onboard calibrator after launch was in a different state from imaging, the calibration of CCD image got a series of difficulties involved. In practice, two methods are used in the processing on the ground station: One is extracting calibration data by statistics from the image itself, and the other is the method of histogram match. It was proved that the latter can calibrate the image much better, because it can remove the effect of unstable response of the camera largely and also can overcome the nonlinearity of the camera basically by using Look-Up Table (LUT) calculated from histogram statistics of different temporal images. Considering the problems of CBERS-01, a lot of calibration tests were done before the launch of CBERS-02, in which a set of lab coefficients for relative calibration was formulated after the data collection by using integration-hemisphere in the stage of satellite assembly test. During the on-orbit test, it was found that the calibration result from such coefficients was not satisfying, especially there being response difference between 3 detector arrays, which was attributed to the unstable dark currents of the CCD camera. This paper comes up with a statistic method to remove such response difference. In this method the middle detector array was used as reference to find the response differences of adjacent similar features between these arrays and it was proved to have a broad adaptability.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Lei, X. W., Wu, J. L., Liu, J. R., Application in calibration correction based on on-board calibration data CBERS-1, Beijing: Remote Sensing for Land & Resources (in Chinese), 2003 (3): 63–66.

    Google Scholar 

  2. Chen, J. S., Zhu, B. Q., Shao, Y., Removal of stripe noises of multi-band remote sensing images based on wavelet, Remote Sensing Information (in Chinese), 2003(2): 6–9.

    Google Scholar 

  3. Singh, A., Thematic mapper radiometric correction research and development results and performance, Photogrammetric Engineering & Remote Sensing, 1985: 1379–1383.

  4. Wegener, M., Destriping multiple sensor imagery by improved histogram matching[j], International Journal of Remote Sensing, 1990(11): 859–875.

    Article  Google Scholar 

  5. Horn, B. K. P., Woodham, R. J., Destriping landsat MSS images by histogram modification, Computer Graphics and Image Processing, 1979, 10: 69–83.

    Article  Google Scholar 

  6. Weinreb, M. P., Xie, R., Lienesch, J. H. et al., Destriping GEOS images by matching empirical distribution functions, Remote Sensing of Environment, 1989, 29: 185–195.

    Article  Google Scholar 

  7. Chen, S. P., The Design and Test of Spatial Camera (in Chinese), Beijing: Astronautics Press, 2003, 270–276.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Guo Jianning.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Guo, J., Yu, J., Zeng, Y. et al. Study on the relative radiometric correction of CBERS satellite CCD image. Sci. China Ser. E-Technol. Sci. 48 (Suppl 2), 12–28 (2005). https://doi.org/10.1007/BF03039422

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03039422

Keywords

Navigation