The use of paired proportional counters, constructed from A-150 tissue equivalent plastic (TEP) and A-150 TEP loaded with an appropriate amount of10B (50 to 200 ppm), for the dosimetry of the boron neutron capture reaction has been investigated for several years at the Gershenson Radiation Oncology Center. This method has been used for determining the dose components (fast neutron, γ ray and boron capture product dose) in both Boron Neutron Capture Therapy (BNCT) beams and in beams proposed for boron neutron capture enhancement of fast neutron therapy (BNCEFNT). A disadvantage of this method, when standard 1/2" diameter Rossi type proportional counters are used, is that the beam intensity must be relatively low in order to avoid saturation effects (pulse pile-up) in the counter. This is a major problem if measurements are to be made in a reactor beam, since reducing the beam intensity generally results in a change in the neutron spectrum. In order to overcome this problem, miniature cylindrical proportional counters have been developed which may be used in high intensity beams. The operational characteristics of these counters are compared with the standard 1/2" spherical counters. A further disadvantage of proportional counters is the relatively long time it takes to collect data, particularly if detailed information (depth-dose curves and beam profiles) is required. This problem could be overcome by using a set of ionization chambers (an A-150 TEP chamber, a Mg chamber and a Mg chamber with a 25 μm boron loaded inner wall) which can be scanned in a water phantom. After calibration against the paired proportional counters it should be possible to extract the fast neutron, γ ray and boron neutron capture product doses from measurements made with these three ionization chambers. A set of such chambers has been used to make preliminary measurements in a fast neutron beam and the results of these measurements are presented.
Similar content being viewed by others
References
Crossman JSP, Watt DE, Enderes D. Improved proton-edge calibration in lineal energy of T.E.P.C. microdosimeters. Proceedings of the 12th Symposium on Microdosimetry, 1996.
Eickel R, Booz J. The influence of the counter wall and the counter shape on the spectral energy deposition in small volumes by60Co gamma-rays and 200 kV X-rays. Rad Environm Biophys 1976;13:145–65.
International Commission on Radiological Protection. ICRP Publication 23: Report of the Task Group on Reference Man. Pergamon Press, Oxford, 1975.
International Commission on Radiation Units and Measurements: ICRU Report 36: Microdosimetry. Bethesda, MD, 1983.
Kellerer AM. Criteria for the equivalence of spherical and cylindrical proportional counters in microdosimetry. Rad Res 1981;86:277–86.
Kota C, Maughan RL, Forman JD. A modified fast neutron beam for boron neutron capture enhanced fast neutron therapy. Proceedings of the Seventh International Symposium on Neutron Capture Therapy for Cancer, 1997 (in press).
Ludemann L, Matzen T, Matzke M, et al. Determination of the thermal neutron flux in a fast neutron beam by use of a boron-coated ionization chamber. Med Phys 1995;22:1743–7.
Wuu CS, Amols HI, Kliauga P, et al. Microdosimetry for boron neutron capture therapy. Rad Res 1992;130:355–9.
Zoetelief J, Schlegel-Bickman D, Schraube H, et al. Characteristics of Mg/Ar ionisation chambers used as gamma-ray dosemeters in mixed neutron-photon fields. Phys Med Biol 1986;31:1339–51.
Author information
Authors and Affiliations
Corresponding author
Additional information
This work has been supported in a part by a grant from the US Department of Energy, Grant # DE-FG02-96ER62217.
Rights and permissions
About this article
Cite this article
Burmeister, J., Kota, C. & Maughan, R.L. Dosimetry of the boron neutron capture reaction for BNCT and BNCEFNT. Strahlenther Onkol 175 (Suppl 2), 115–118 (1999). https://doi.org/10.1007/BF03038908
Issue Date:
DOI: https://doi.org/10.1007/BF03038908