Skip to main content
Log in

Treatment planning for the heavy-ion facility at GSI

  • Accelerator and Medical Physics
  • Published:
Strahlentherapie und Onkologie Aims and scope Submit manuscript

Summary

A new treatment planning program was developed for the heavy-ion therapy facility at GSI. In addition, a concise quality standard for treatment planning has been set up. It covers acceptance and constancy checks of all critical aspects in treatment planning. Dose verification measurements done during the commissioning phase show an overall good agreement with the treatment planning calculations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Haberer T, Becher W, Schardt D, et al. Magnetic scanning system for heavy ion therapy. Nucl Instr Meth 1993;A330:296–305.

    Article  Google Scholar 

  2. Heeg P, Hartmann G, Jäkel O, et al. Quality assurance at the heavy ion therapy facility at GSI this proceedings.

  3. Gademann G, Schlegel W, Bürkelbach J, et al. Dreidimensionale Bestrahlungsplanung — Untersuchungen zur klinischen Integration. Strahlenther Onkol 1993;169:159–67.

    PubMed  CAS  Google Scholar 

  4. Bendl R. Virtuelle Therapiesimulation. In: Schlegel W, Bortfeld T, Stein J, Eds. Dreidimensionale Strahlentherapieplanung. Heidelberg: DKFZ. 1995:31–42.

    Google Scholar 

  5. Krämer M, Jäkel O. Therapy planning for heavy ion irradiation. In: Amaldi U, Larsson B, Lemoigne Y, Eds. Advances in Hadrontherapy. Amsterdam: Elsevier, 1997:351–8.

    Google Scholar 

  6. Haberer T. Entwicklung eines magnetischen Strahlführungssystems zur tumorkonformen Strahlentherapie mit schweren geladenen Teilchen. GSI-Report 1994; GSI-94-09.

  7. Heinrich W, Wiegel B, Kraft G. ß, Zeff, dE/dx, range and restricted energy loss of heavy ions in the region 1<E<1000 MeV/u. GSI-Report 1991; GSI-91-30.

  8. Jacob C. Reichweite-CT-Zahl-Beziehung von Phantommaterialien und Messungen mit einer neuentwickelten multisegmentierten lonisationskammer zur Dosisverifikation bei Schwerionenbestrahlung. Dissertation. Heidelberg, 1996.

  9. Scholz M, Kraft G, Track structure and the calculation of biological effects of heavy charged particles. Adv Space Res 1996;18 1/2:5–14.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Oliver Jäkel.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jäkel, O., Krämer, M., Hartmann, G.H. et al. Treatment planning for the heavy-ion facility at GSI. Strahlenther Onkol 175 (Suppl 2), 15–17 (1999). https://doi.org/10.1007/BF03038878

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03038878

Key Words

Navigation