Application of LPME/GC-ECD for determination of PCP in water

  • Published:
Science in China Series B: Chemistry Aims and scope Submit manuscript

Abstract

Liquid-phase microextraction (LPME) followed by gas chromatography (GC) coupled with an electron capture detector (ECD) was applied for the analysis of pentachlorophenol (PCP) in aqueous samples. After alkalization with Na2CO3 solution, PCP was acetylated with acetic anhydride. The pentachlorophenyl acetate derivative was then extracted with n-hexane by LPME. 1.5 μL organic drop exposed to the aqueous sample solution at 15°C for 5 min, stirring rate at 100 r/min was chosen as the optimum extraction condition. Under this condition, LPME provided a very simple, fast and solvent-less procedure to collect PCP from aqueous sample for GC determination. The linearity of LPME/GC-ECD for PCP in distilled water was investigated at the range of 2–200 μg/L with a coefficient of correlation 0.998. The repeatability of this method was determined at the level of 50 μg/L with the average of relative standard deviations (RSDs) 7%. Detection limit was obtained at less than 0.5 μg/L levels. When LPME/GC-ECD was applied to the determination of PCP in municipal sewage, the average of relative recoveries and RSDs were 70% and 6.5%, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Crosby, D. G., Environmental chemistry of pentachlorophenol, Pure Appl. Chem., 1981, 53: 1051–1080.

    Article  Google Scholar 

  2. Zheng, M. H., Zhang, B., Bao, Z. G. et al., Analysis of pentachlorophenol from water, sediments, and fish bile of Dongting Lake in China, Bull. Environ. Contain. Bull. Environ. Contain. Toxicol., 2000, 64: 16–19.

    Article  CAS  Google Scholar 

  3. Li Hou, Wen, X. J., Tu, C. H. et al., Combination of liquid-phase microextraction and on-column stacking for trace analysis of amino alcohols by capillary electrophoresis, Journal of Chromatography A, 2002, 979: 163–169.

    Article  Google Scholar 

  4. Jeannot, M. A., Cantwell, F. F., Solvent microextraction into a single drop, Anal. Chem., 1996, 68: 2236–2240.

    Article  CAS  Google Scholar 

  5. Jeannot, M. A., Cantwell, F. F., Mass transfer characteristics of solvent extraction into a single drop at the tip of a syringe needle, Anal. Chem., 1997, 69: 235–239.

    Article  CAS  Google Scholar 

  6. He, Y., Lee, H. K., Liquid-phase microextraction in a single drop of organic solvent by using a conventional microsyringe, Anal. Chem., 1997, 69: 4634–4640.

    Article  CAS  Google Scholar 

  7. Zhao, L. M., Lee, H. K., Application of static liquid-phase microextraction to the analysis of organochlorine pesticides in water, Journal of Chromatography A, 2001, 919: 381–388.

    Article  CAS  Google Scholar 

  8. Liu Wuping, Lee, H. K., Continuous-flow microextraction exceeding 1000-fold concentration of dilute analytes, Anal. Chem., 2000, 72: 4462–4467.

    Article  CAS  Google Scholar 

  9. Wang, Y., Kwok, Y. C., He, Y. et al., Application of dynamic liquid-phase microextraction to the analysis of chloroben- zenes in water by using a conventional microsyringe, Anal. Chem., 1998, 70: 4610–4614.

    Article  CAS  Google Scholar 

  10. Solveig, A., Halvorsen, T. G., Stig, P. B., Liquid-phase microextraction combined with capillary electrophoresis, a promising tool for the determination of chiral drugs in biological matrices, Journal of Chromatography A, 2002, 963: 303–312.

    Article  Google Scholar 

  11. Tung, S. H., Stig, P B., Knut, E. R., Recovery, enrichment and selectivity in liquid-phase microextraction comparison with conventional liquid-liquid extraction, Journal of Chromatography A, 2002, 963: 3–17.

    Article  Google Scholar 

  12. Li, H., Gang, S., Lee, H. K., Automated hollow fiber-protected dynamic liquid-phase microextraction of pesticides for gas chromatography-mass spectrometric analysis, Journal of Chromatography A, 2003, 985: 107–116.

    Article  Google Scholar 

  13. Lee, M. R., Yeh, Y. C., Hsiang, W. S. et al., Application of solid-phase microextraction and gas chromatography-mass spectrometry for the determination of chlorophenols in urine, Journal of Chromatography B, 1998, 707: 91–97.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ping Li.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, P., Liu, J. Application of LPME/GC-ECD for determination of PCP in water. Sc. China Ser. B-Chem. 46, 481–486 (2003). https://doi.org/10.1007/BF03036890

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03036890

Keywords

Navigation