Abstract
Although considerable efforts have been directed toward improving imaging agents and imaging equipment, relatively little attention has been give to factors that optimize image interpretation. Stress myocardial perfusion images are often interpreted by visual inspection alone. This may introduce considerable inter- and intraobserver variability. Importantly, clinical usefulness of myocardial perfusion imaging may not be consistently reproduced in many laboratories using visual analysis. Relative myocardial distribution of imaging agents on either planar or single-photon emission computed tomographic images can be readily quantified and compared with normal data files by computer processing. Quantification of myocardial perfusion images provides a reproducible measure of the extent of perfusion abnormalities and defect reversibility. The extent of perfusion abnormalities has been shown to have prognostic significance. Computer quantification of myocardial perfusion images improves not only the overall diagnostic yield but also enhances reliability, accuracy, confidence, and reproducibility of interpretation.
Similar content being viewed by others
References
Trobaugh GB, Wackers EJTh, Sokole EB, DeRouen TA, Ritchie JL, Hamilton GW. Thallium-201 myocardial imaging: an interinstitutional study of observer variability. J Nucl Med 1977;19:359–63.
Wackers FJTh, Mattera J. Optimizing planar Tl-201 imaging: computer quantification. Cardio 1990;7:103–12.
Smith WH, Watson DD. Technical aspects of myocardial planar imaging with technetium-99m sestamibi. Am J Cardiol 1990;66:16E-22E.
Garcia EV, Cooke CD, van Train KF, et al. Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi. Am J Cardiol 1990;66:23E-31E.
Wackers FJTh, Bodenheimer M, Fleiss JL, Brown M, MSSMI Tl-201 Investigators: Factors affecting uniformity in interpretation of planar Tl-201 imaging in a multicenter trial. J Am Coll Cardiol 1993;21:1064–74.
Watson DD, Campbell NP, Read EK, Gibson RS, Teates CD, Beller GA. Spatial and temporal quantitation of plane thallium myocardial images. J Nucl Med 1981;22:577–84.
Garcia E, Maddahi J, Berman D, Waxman A. Space time quantitation of thallium-201 myocardial scintigraphy. J Nucl Med 1981;22:309–17.
Klein JL, Garcia EV, DePuey EG, et al. Reversibility bull’s eye: a new polar bull’s eye map to quantify reversibility of stress-induced SPECT thallium-201 myocardial perfusion defects. J Nucl Med 1990;31:1240–6.
DePuey EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. J Nucl Med 1989;30:441–9.
Wackers FJTh. Artifacts in planar and SPECT myocardial perfusion imaging. Am J Cardiac Imaging 1992;6:42–58.
Berger BC, Watson DD, Taylor GJ, et al. Quantitative thallium-201 exercise scintigraphy for detection of coronary artery disease. J Nucl Med 1981;22:585–93.
Maddahi J, Garcia EV, Berman DS, Waxman A, Swan HJC, Forrester J. Improved noninvasive assessment of coronary artery disease by quantitative analysis of regional stress myocardial distribution and washout of thallium-201. Circulation 1981;64:924–35.
Kaul S, Boucher CA, Newell JB, et al. Determination of the quantitative thallium imaging variables that optimize detection of coronary artery disease. J Am Coll Cardiol 1986;7:527–37.
van Train KF, Berman DS, Garcia EV, et al. Quantitative analysis of stress thallium-201 myocardial scintigrams: a multicenter trial. J Nucl Med 1986;27:17–25.
Tamaki N, Yonekura Y, Mukai T, et al. Stress thallium-201 transaxial emission computed tomography: quantitative versus qualitative analysis for evaluation of coronary artery disease. J Am Coll Cardiol 1984;4:1213–21.
DePasquale EE, Nody Ac, DePuey EG, et al. Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease. Circulation 1988;77:316–27.
Borges-Neto S, Mahmarian JJ, Jain A, Roberts R, Verani MS. Quantitative thallium-201 single photon emission computed tomography after oral dipyridamole for assessing the presence, anatomic location and severity of coronary artery disease. J Am Coll Cardiol 1988;11:962–9.
Maddahi J, Van Train K, Prigent F, et al. Quantitative single photon emission computed thallium-201 tomography for detection and localization of coronary artery disease: optimization and prospective validation of a new technique. J Am Coll Cardiol 1989;14:1689–99.
Fintel DJ, Links JM, Brinker JA, Frank TL, Parker M, Becker LC. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis. J Am Coll Cardiol 1989;13:600–12.
Iskandrian S, Heo J, Kong B, Lyons E. Effect of exercise level on the ability of thallium-201 tomographic imaging in detecting coronary artery disease: analysis of 461 patients. J Am Coll Cardiol 1989;14:1477–86.
Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Robets R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease. J Am Coll Cardiol 1990;15:318.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wackers, F.J.T. Science, art, and artifacts: How important is quantification for the practicing physician interpreting myocardial perfusion studies?. J Nucl Cardiol 1 (Suppl 5), S109–S117 (1994). https://doi.org/10.1007/BF03032556
Issue Date:
DOI: https://doi.org/10.1007/BF03032556