  3. Article

High frequency oscillatory ventilation in the management of a high output bronchopleural fistula: a case report

L’utilisation de la ventilation oscillatoire à haute fréquence dans la prise en charge d’une fistule bronchopleurale à débit élevé: une étude de cas

  • Neuroanesthesia and Intensive Care
  • Published: January 2004
  • volume 51, pages 78–83 (2004)
Download PDF
Canadian Journal of Anesthesia Aims and scope Submit manuscript
High frequency oscillatory ventilation in the management of a high output bronchopleural fistula: a case report
Download PDF
  • Duc V. Ha1 &
  • David Johnson1 
  • 931 Accesses

  • 31 Citations

  • Explore all metrics

Cite this article

Abstract

Purpose

To describe the use of high frequency oscillatory ventilation (HFOV) in the management of a high output bronchopleural fistula (BPF).

Clinical features

A 55-yr-old female developed a BPF after thoracotomy and decortication of an empyema. The patient deteriorated on the second postoperative day (pH 7.10 PCO2 89) requiring 100% oxygen and mechanical ventilation. After initial improvement, deterioration occurred by 24 hr with conventional positive pressure ventilation (volume or pressure limited) because of decreased pulmonary compliance and bilateral diffuse airspace disease (acute respiratory distress syndrome), persistent increased peak and plateau airway pressures, a prolonged inspired oxygen concentration greater than 0.6, and inability to apply positive end expiratory pressures because of an increased BPF leak (530 mL · breaths−1). HFOV was initiated and maintained for 28 days until resolution of the airspace disease and decreased leak through the BPF to 100 mL · breaths−1.

Conclusion

We report the successful use of HFOV in a patient with high output BPF We suggest that HFOV is a useful technique in patients with a BPF when conventional positive pressure ventilation fails.

Objectif

Décrire l’usage de la ventilation oscillatoire à haute fréquence (VOHF) dans la prise en charge d’une fistule bronchopleurale (FBP) à débit élevé.

Éléments cliniques

Une FBP s’est développée chez une femme de 55 ans à la suite d’une thoracotomie et de la décortication d’un empyème. L’état de la patiente s’est détérioré au deuxième jour postopératoire (pH 7,10 PCO2 89) et a nécessité l’utilisation d’oxygène à 100 % et de ventilation mécanique. Une amélioration initiale a été notée, suivie d’une détérioration, 24 h après l’instauration de la ventilation traditionnelle à pression positive (pression ou volume limité), causée par une baisse de la compliance pulmonaire et un trouble alvéolaire diffus (syndrome de détresse respiratoire aiguë), la hausse de la pression de pointe et de la pression plateau des voies aériennes, la persistance d’une concentration d’oxygène inspirée plus grande que 0,6 et l’incapacité d’appliquer des pressions positives expiratoires à cause des fuites par la FBP (530 mL · respirations−1). La VOHF a été installée et maintenue pendant 28 jours jusqu’à la résolution du trouble respiratoire et la diminution de la fuite à 100 mL · respirations−1.

Conclusion

L’efficacité de la VOHF chez une patiente qui présentait une FBP à débit élevé semble donc indiquer son utilité devant l’échec de la ventilation traditionnelle à pression positive en présence d’une FBP.

Article PDF

Download to read the full article text

Similar content being viewed by others

Bronchopleural Fistulae

Chapter © 2019

High-frequency oscillatory ventilation guided by transpulmonary pressure in acute respiratory syndrome: an experimental study in pigs

Article Open access 09 May 2018

Philipp Klapsing, Onnen Moerer, … Jan Florian Heuer

Management of pneumothorax in hemodynamically stable preterm infants using high frequency oscillatory ventilation: report of five cases

Article Open access 22 December 2017

Claudia Aurilia, Cinzia Ricci, … Giovanni Vento

Use our pre-submission checklist

Avoid common mistakes on your manuscript.

References

  1. Powner DJ, Grenvik A. Ventilatory management of life-threatening bronchopleural fistulae. A summary. Crit Care Med 1981; 9: 54–8.

    Article  PubMed  CAS  Google Scholar 

  2. Litmanovitch M, Joynt GM, Cooper PJF, Kraus P. Persistent bronchopleural fistula in a patient with adult respiratory distress syndrome. Treatment with pressure-controlled ventilation. Chest 1993; 104: 1901–2.

    Article  PubMed  CAS  Google Scholar 

  3. Pierson DJ, Horton CA, Bates PW. Persistent bron-chopleural air leak during mechanical ventilation. A review of 39 cases. Chest 1986; 90: 321–3.

    Article  PubMed  CAS  Google Scholar 

  4. Bishop MJ, Benson MS, Sato P, Pierson DJ. Comparison of high-frequency jet ventilation with conventional mechanical ventilation for bronchopleural fistula. Anesth Analg 1987; 66: 833–8.

    Article  PubMed  CAS  Google Scholar 

  5. Vincken W, Cosio MG. Clinical applications of high-frequency jet ventilation. Intensive Care Med 1984; 10: 275–80.

    Article  PubMed  CAS  Google Scholar 

  6. Rubio JJ, Algora-Weber A, Dominguez-de Villota E, Chamorro C, Mosquera JM. Prolonged high-frequency jet ventilation in a patient with bronchopleural fistula. An alternative mode of ventilation. Intensive Care Med 1986; 12: 161–3.

    Article  PubMed  CAS  Google Scholar 

  7. Roth MD, Wright JW, Bellamy PE. Gas flow through a bronchopleural fistula. Measuring the effects of high-frequency jet ventilation and chest-tube suction. Chest 1988; 93: 210–3.

    Article  PubMed  CAS  Google Scholar 

  8. Campbell D, Steinmann M, Porayko L. Nitric oxide and high frequency jet ventilation in a patient with bilateral bronchopleural fistula and ARDS. Can J Anesth 2000; 47: 53–7.

    Article  PubMed  CAS  Google Scholar 

  9. Riphagen S, Bohn D. High frequency oscillatory ventilation. Intensive Care Med 1999; 25: 1459–62.

    Article  PubMed  CAS  Google Scholar 

  10. Brambrink AM, Brachlow J, Weiler N, et al. Successful treatment of a patient with ARDS after pneumonectomy using high-frequency oscillatory ventilation. Intensive Care Med 1999; 25: 1173–6.

    Article  PubMed  CAS  Google Scholar 

  11. Varkul MD, Stewart TE, Lapinsky SE, Ferguson ND, Mehta S. Successful use of combined high-frequency oscillatory ventilation, inhaled nitric oxide, and prone positioning in the acute respiratory distress syndrome. Anesthesiology 2001; 95: 797–9.

    Article  PubMed  CAS  Google Scholar 

  12. Mehta S, Lapinsky SE, Hallett DC, et al. Prospective trial of high-frequency oscillation in adults with acute respiratory distress syndrome. Crit Care Med 2001; 29: 1360–9.

    Article  PubMed  CAS  Google Scholar 

  13. Krishnan JA, Brower RG. High-frequency ventilation for acute lung injury and ARDS. Chest 2000; 118: 795–807.

    Article  PubMed  CAS  Google Scholar 

  14. Smith RB. Ventilation at high respiratory frequencies. High frequency positive pressure ventilation, high frequency jet ventilation and high frequency oscillation. Anaesthesia 1982; 37: 1011–8.

    Article  PubMed  CAS  Google Scholar 

  15. Feeley TW, Keating D, Nishimura T. Independent lung ventilation using high-frequency ventilation in the management of a bronchopleural fistula. Anesthesiology 1988; 69: 420–2.

    Article  PubMed  CAS  Google Scholar 

  16. Benjaminsson E, Klain M. Intraoperative dual-mode independent lung ventilation of a patient with bron-chopleural fistula. Anesth Analg 1981; 60: 118–9.

    Article  PubMed  CAS  Google Scholar 

  17. Mortimer AJ, Laurie PS, Garrett H, Kerr JH. Unilateral high frequency jet ventilation. Reduction of leak in bronchopleural fistula. Intensive Care Med 1984; 10: 39–41.

    Article  PubMed  CAS  Google Scholar 

  18. Crimi G, Candiani A, Conti G, Mattia C, Gasparetto A. Clinical applications of independent lung ventilation with unilateral high-frequency jet ventilation (ILV-UHFJV). Intensive Care Med 1986; 12: 90–4.

    Article  PubMed  CAS  Google Scholar 

  19. Baumann MH, Sahn SA. Medical management and therapy of bronchopleural fistulas in the mechanically ventilated patient. Chest 1990; 97: 721–8.

    Article  PubMed  CAS  Google Scholar 

  20. Chaddouk EG. Bronchopleural fistula and mechanical ventilation: a simple technique of management? J Thorac Cardiovasc Surg 1995; 110: 1141–3.

    Article  PubMed  CAS  Google Scholar 

  21. Gallagher TJ, Smith RA, Kirby RR, Civetta JM. Intermittent inspiratory chest tube occlusion to limit bronchopleural cutaneous airleaks. Crit Care Med 1976; 4: 328–32.

    Article  PubMed  CAS  Google Scholar 

  22. Anonymous. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome The Acute Respiratory Distress Syndrome Network. N Engl J Med 2000; 342: 1301–8.

  23. Parker JC, Hernandez LA, Peevy KJ. Mechanisms of ventilator-induced lung injury. Crit Care Med 1993; 21: 131–43.

    Article  PubMed  CAS  Google Scholar 

  24. Singh JM, Stewart TE. High-frequency mechanical ventilation principles and practices in the era of lung-protective ventilation strategies. Resp Care Clin N Am 2002; 8: 247–60.

    Article  Google Scholar 

  25. Mehta S, MacDonald R. Implementing and troubleshooting high-frequency oscillatory ventilation in adults in the intensive care unit. Resp Care Clin N Am 2001; 7: 683–95.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

  1. Department of Anesthesiology, Royal University Hospital 103 Hospital Drive, University of Saskatchewan, S7N 0W8, Saskatoon, Saskatchewan, Canada

    Duc V. Ha & David Johnson

Authors
  1. Duc V. Ha
    View author publications

    You can also search for this author in PubMed Google Scholar

  2. David Johnson
    View author publications

    You can also search for this author in PubMed Google Scholar

Corresponding author

Correspondence to Duc V. Ha.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Ha, D.V., Johnson, D. High frequency oscillatory ventilation in the management of a high output bronchopleural fistula: a case report. Can J Anesth 51, 78–83 (2004). https://doi.org/10.1007/BF03018553

Download citation

  • Revised: 24 September 2002

  • Accepted: 03 September 2003

  • Issue Date: January 2004

  • DOI: https://doi.org/10.1007/BF03018553

Share this article

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Keywords

  • Tidal Volume
  • Acute Lung Injury
  • Acute Respiratory Distress Syndrome
  • Conventional Mechanical Ventilation
  • Bronchopleural Fistula
Use our pre-submission checklist

Avoid common mistakes on your manuscript.

Advertisement

search

Navigation

  • Find a journal
  • Publish with us

Discover content

  • Journals A-Z
  • Books A-Z

Publish with us

  • Publish your research
  • Open access publishing

Products and services

  • Our products
  • Librarians
  • Societies
  • Partners and advertisers

Our imprints

  • Springer
  • Nature Portfolio
  • BMC
  • Palgrave Macmillan
  • Apress
  • Your US state privacy rights
  • Accessibility statement
  • Terms and conditions
  • Privacy policy
  • Help and support

34.229.63.28

Not affiliated

Springer Nature

© 2023 Springer Nature