Summary
The anaesthetist is well qualified as a specialist to train other doctors and lay personnel in methods of resuscitation. A plea is set forth for a widespread training programme.
The prevention and treatment of respiratory obstruction can be a life-saving procedure in itself, and simple methods for maintaining a clear airway are described. Cases of severe respiratory obstruction in imminent danger of death can be saved by the introduction of a number fourteen trocar through the crico-thyroid membrane, thus providing more ideal conditions for a low tracheotomy.
The time factor is insisted upon in starting manual artificial resuscitation in drowning victims.
Should apparent cardiac arrest accompany cessation of respiration, simple methods of heart stimulation are recommended to be applied simultaneously with artificial respiration.
In an emergency, artificial respiration should be started with immediately available methods such as manual artificial respiration or mouth to mouth breathing.
It is explained that mechanical methods of artificial respiration are intended to replace the operator who has initiated resuscitation by manual methods. Different types of mechanical devices are described and the advantages of self-contained units not requiring a source of compressed air or oxygen to become operative, are made evident.
It is suggested that a bag and mask device be incorporated in all types of automatic resuscitators to meet individual exigencies of lung compliance. The use of a Nomogram for patients undergoing long-term maintenance of artificial respiration in a tank respirator is a simple practical means of avoiding consequences of overventilation or hypoventilation.
Cuirass type respirators and the rocking bed are considered as weaning devices and are not recommended for use in apneic patients with low lung or thoracic compliance.
A new type of infant resuscitator incorporating the Fink modification of the Stephen-Slater valve is presented and described. The resuscitator is a selfcontained easily transportable unit which is simple in design and operation. It is intended for routine use and is operated at controlled pressures. It is not to be confused with the G.B.L. hand resuscitator which operates at high mask pressures and time limited impulses.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Sadove, M.S., Gittelson, L.A., Wyant, G.M. &Holinger, P. The Maintenance of an Efficient Tracheobronchial Airway. Am. Pract.5: 11 (Jan. 1954).
Reed, J.P.R., Kemph, J.P., Hamelberg, W., Hitchcook, F.A. &Jacoby, J. Studies with Transtracheal Artificial Respiration. Anesthesiology15: 28 (Jan. 1954).
Drinker, C.K. Physiologic Principles of Resuscitation and Oxygen Therapy. Postgrad. Med2 471 (Jan. 1952).
Djourno, A. Methodes recentes cle respiration artificielle. Presse méd.61: 385 (March 18, 1953).
Sadove, M.S., Gordon, A S , Nelson, J.T. &Ivy, A.C. Barbiturate-Curare Induced Apnea for Artificial Respiration Studies m Normal Adults J. Appl. Physiol.4: 403 (Dec 1951).
Nime, R.G., Conner, E.H., Botelho, S.Y., &Comroe, J.H., Jr. A Comparison of Methods for Performing Manual Artificial Respiration on Apneic Patients. J. Appl. Physiol.4 486 (Dec. 1951).
Whittenberger, J.L., Affeldt, J.E. , Goodale, W.T. &Sarnoff, S.J. The Mechanics of Breathing in Relation to Manual Methods of Artificial Respiration. J. Appl. Physiol.4: 476 (Dec. 1951).
Karpovich, P V , Hale, C.J., &Bailey, T.L. Pulmonary Ventilation in Manual Artificial Respiration A Study m Manual Artificial Respiration J. Appl. Physiol.4: 458 (Dec. 1951).
Gordon, A.S., Sadove, M.S. &Raymon, F. Critical Survey of Manual Artificial Respiration J A.M A.147: 1454 (Dec 8, 1951).
Whittenberger, J L. Resuscitation and Other Uses of Artificial Respiration. New England J Med.251. 775 (Nov. 4, 1954),251. 816 (Nov 11,1954).
Hale, D.E. Anesthesiology. Philadelphia: F A Davis Company (1954)
Kreiselman, J A New Resuscitation Apparatus Anesthesiology4: 6 (1943).
— The Treatment of Asphyxia Connecticut Med. J9: 2 (1945).
Whittenberger, J.L., Affeldt, J E, &Mead, J Physical Properties of Lungs in Experimental Pulmonary Oedema. Federation Proc11: 172 (1952).
Radford, E.P., Jr,Ferris, B.G., Jr., &Kriete, B.C.. Clinical Use of a Nomogram to Estimate Proper Ventilation during Artificial Respiration New England J Med.251: 877 (Nov. 25, 1954).
Fink, B.R.A. Nonrebreathmg Valve of New Design Anesthesiology15, 471–474 (Sept. 1954)
Whittenberger, J.L. Artificial Respiration and its Clinical Applications. Seminar17: 20–28 (1955)
Goddard, R F The Role of an Infant Resuscitation Team in Investigative Studies of Respiratory Onset at Birth Anesth & Analg34 1–25 (Jan-Feb. 1955).
Day, R., Goodfellow, A M , Apgar, V &Beck, G J. Pressure-Time Relations in the Safe Correction of Atelectasis in Animal Lungs Ped10: 593 (1952)
Author information
Authors and Affiliations
Additional information
Presented before the Annual Meeting, Canadian Anaesthetists’ Society, Toronto, Ont., June 21, 1955.