Abstract
We have investigated sensible respiratory loss, which is usually taken as the product of expired volume and the temperature difference between inspired and expired air (Ve × ΔT). Air temperature was measured with a 0.122 mm copper-constantan thermocouple mounted in the mouthpiece of a T-piece breathing system, and expired volume with a pneumotachograph. Changing air temperature (ΔT) at the mouth and expired air volume (Ve) were recorded simultaneously while the subject voluntarily breathed at different tidal volumes and rates. Inspired temperatures were controlled at 12.05°C, 21.80°C and 25.74° C at a low dewpoint temperature of 4–5° C.
Temperature volume “loops” were constructed using an x-y plotter. The areas of each “loop” and enclosing rectangle (Ve × ΔT) were measured. The difference was divided by the weight of the rectangle to give the percentage of overestimation of sensible heat loss, which ranged from 5.5 to 17.2 per cent. The error increased significantly with decreasing tidal volume and increasing respiratory rate.
Résumé
Nous avons étudié les pertes caloriques sensibles de l’arbre trachéobronchique qui sont habituellement obtenues en faisant le produit du volume expire par la difference de température entre l’air inspiré et l’air expiré (Ve × ΔT). La température de l’air a été mesurée par un thermocouple cuivre-constantan de 0.122 mm monté sur une pièce buccale placée sur une pièce en T. Le volume expiré était mesuré par un pneumotochographe. La différence de température à la bouche (ΔT) et le volume d’air expiré (Ve) étaient enregistrés simultanément alors que le sujet respirait à différents volumes courants et à différentes fréquences. Les températures inspirées étaient réglées à 12.05°C, 21.80°C, et 25.74°C et la température du point de rosée était maintenue à 4–5° C.
Les courbes température-volume ont été construites en utilisant un axe x-y. Les surfaces de chaque courbe et du rectangle la renfermant (Ve × ΔT) ont été mesurées. La différence a été divisée par le poids du rectangle pour donner le pourcentage de surestimation des pertes caloriques sensibles, lequel se situait entre 5.5 et 17.2 pour cent. L’erreur augmente de faqon significative lorsque le volume courant diminue et que la fréquence respiratoire augmente.
Article PDF
Similar content being viewed by others
References
Piantandosi CA, Thalmann ED, Spaur WH. Metabolic response to respiratory heat loss-induced core cooling. J Appt Physiol 1981; 50:829–34.
Hanson R deG. Respiratory heat loss at increased core temperature. J Appl Physiol 1974; 37:103–7.
McCutchan JW, Taylor CL. Respiratory heat exchange with varying temperature and humidity of inspired air. J Appl Physiol 1951; 4:121–35.
Snellen JW, Chang KS, Smith W. Technical description and performance characteristics of a human whole-body calorimeter. Med Biol Eng Comput 1983;21:9–20.
Byles PH. Observations on some continuously- acting spirometers. Brit J Anaesth 1960; 32:470–5.
Snedecor GW, Cochran WG. Statistical Methods, 6th ed., Ames: Iowa State University Press, 1967.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
King, F.G., Manson, H.J., Snellen, J.W. et al. Demonstration of a problem in estimating sensible heat loss from the respiratory tract by thermometry. Can Anaesth Soc J 31, 460–465 (1984). https://doi.org/10.1007/BF03015426
Issue Date:
DOI: https://doi.org/10.1007/BF03015426