Summary
Althesin in dose ranges of 40, 60 and 80 μl/Kg was administered to.six healthy unpremedicated volunteers according to a balanced incomplete block design. Both subjective and objective changes resulting from the administration of the agent were studied and analyzed.
In the dose ranges used, Althesin was found to have no deleterious effects on heart rate, respiratory rate or blood pressure and apnoea only occurred in one patient who had an end-expiratory CO2 level lower than normal, due to preanaesthetic hyperventilation. The onset of sleep is prolonged with Althesin at the injection rate of 1 ml/10 secs. The onset of anaesthesia is not influenced by the total dose, but the sleep time is directly proportional to the dose injected. Auditory evoked responses tended to lie on a curve which might indicate that with increasing dose the time to reappearance of these responses is not correspondingly prolonged. However, this last observation must be confirmed by studies on a larger scale.
Résumé
Six sujets volontaires en bonne santé, non prémédiqués, ont reçu de l’althesin à des doses de 40,60 et 80 μ1/kg, selon un plan d’analyse de bloc “randomisé”.
Les effets tant subjectifs qu’objectifs de cette médication ont été étudiés et analysés. Pour des doses d’althesin de cet ordre, on n’a pas constaté d’effet nocif sur les fréquences cardiaque et respiratoire et sur la pression artérielle. Un sujet seulement a présenté une période d’apnée mais celui-ci avait déjà au départ une hypocapnie vraisemblablement due à de l’hyperventilation pré-anesthésique.
L’endormissement est prolongé au taux d’injection de 1 ml/10 sec utilisé dans cette étude, il est cependant indépendant de la dose totale. La durée du sommeil pour sa part est en fonction directe de la dose injectée.
Les réactions aux stimuli auditifs, c’est à dire le moment où on peut constater une activité vasculaire en réponse à une sollicitation verbale, ont tendance à s’inscrire sur une courbe dont la forme indiquerait que l’augmentation de la dose ne s’accompagne pas nécessairement d’un retard proportionnel du moment d’ap-parition de ces réactions.
Cependant, d’autres études sur une plus grande échelle devront confirmer cette observation.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Selye, H. Anaesthetic effects of steroid hormones. Proc. Soc. Exper. Biol. Med.46: 116–121 (1941).
Robertson, S.D. &Wynn Williams, A. Studies on clinical and pathological effects of hydroxydione. Anaesthesia16: 389–409 (1961).
Vickers, M.D. The measurement of recovery from anaesthesia. Brit. J. Anaesth.37: 296–302 (1965).
Lewis, CD. Statistical Monitoring Techniques. Med. & Biol. Engin.9: 315–323 (1971).
Hope, C.E., Lewis, C.D., Perry, J.R., &Gamble, A. Computed trend analysis in automated patient monitoring systems. Brit. J. Anaesth.45: 440–449 (1973).
Author information
Authors and Affiliations
Additional information
The Study was undertaken within the framework of a Development Grant by the Canadian Foundation for the Advancement of Clinical Pharmacology.
Supplies of Althesin have been made available by Messrs. Glaxo Canada Limited, Toronto.
Rights and permissions
About this article
Cite this article
Hope, C.E., Wilson, T.W. & Wyant, G.M. Some pharmacological properties of althesin (CT1341) in man. Canad. Anaesth. Soc. J. 22, 572–586 (1975). https://doi.org/10.1007/BF03013410
Issue Date:
DOI: https://doi.org/10.1007/BF03013410