Skip to main content

Technical Report The effect of pancuronium on the solubility of aqueous thiopentone

Abstract

n this study we identified the precipitate formed when pancuronium bromide (pH 3.9) and sodium thiopentone (pH 10.6) are combined in vitro. A precipitate formed when sufficient pancuronium was added to thiopentone to decrease the pH below 9,25. The precipitate was isolated, redissolved in alkaline solution and identified as thiopentone using ultraviolet spectrophotometry. Pancuronium was soluble in water in the pH range of 2.0 to 12.0, whereas thiopentone was soluble in water only at a pH greater than 9.90. We conclude that thiopentone precipitates when combined with pancuronium because of a pH-dependent decrease in the solubility of thiopentone, rather than a chemical interaction.

Résumé

Dans cette étude on a identifié le précipité qui se forme à la suite de la combinaison in vitro du bromure de pancuronium (pH 3.9) et du thiopentone de sodium (pH J0.6). Si la quantité de pancuronium est suffisante, un précipité se forme lorsque le pH est en bas de 9.25. Le précipité était isolé, redissout dans une solution alcaline et identifié par spectophotométrie aux rayons ultraviolet comme étant le thiopentone. On a trouvé que le pancuronium était soluble dans ľeau lorsque le pH est aux alentours de 2.0 à 12.0, le thiopentone lui était soluble dans ľeau uniquement à un pH supérieur à 9.90. On conclut que le thiopentone précipite si combiné au pancuronium à cause de la diminution de solubilité du thiopentone qui est relié au pH plutôt qu’à une interaction chimique.

References

  1. Barr A.M., Thornley B.A. Thiopentone and pancuronium crash induction. A comparison with thiopentone and suxamethonium. Anaesthesia. 1978; 33: 25–31.

    PubMed  Article  CAS  Google Scholar 

  2. Lerman J., Kiskiss A.A. Lidocaine attenuates the intraocular pressure response to rapid intubation in children. Can Anaesth Soc J. 1985; 32: 339–45.

    PubMed  CAS  Article  Google Scholar 

Download references

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Morton, W.D., Lerman, J. Technical Report The effect of pancuronium on the solubility of aqueous thiopentone. Can J Anaesth 34, 87 (1987). https://doi.org/10.1007/BF03007694

Download citation

  • DOI: https://doi.org/10.1007/BF03007694

Key words

  • anaesthetics
  • intravenous
  • thiopentone
  • neuromuscular relaxants
  • pancuronium
  • drug interactions
  • pancuronium
  • thiopentone