Skip to main content
Log in

Site calibration for the wind turbine performance evaluation

  • Published:
KSME International Journal Aims and scope Submit manuscript

Abstract

The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine’s hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the TaeKwanRyung test site are presented using three-month wind data from a reference meteorological mast and the other mast temporarily installed at the site of wind turbine. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Antoniou, I., Mouzakis, F., Albers, A. and Follrichs, U., 2001,“Identification of Variables for site calibration and Power Curve Assessment in Complex Terrain (Project JOR3-CT98- 0257),”2001 European Wind Energy Conference, pp. 17–22.

  • Curvers, A., 1999,“Site Calibration at the ECN Test Site,”1999 European Wind Energy Conference, pp. 638–640.

  • Ferreira, M., Rodirigues, A. and Ribeiro, L., 1999,“Evaluation of the Influence of the Installation of a Wind Turbine over the Results of a Nearby Measuring Station,”1999 European Wind Energy Conference, pp. 1185–1188.

  • Hau, E., 2000,Wind Turbines Fundamentals,Technologies, Application and Economics, Springer.

  • Hunter, R. et al, 2001,European Wind Turbine Testing Procedure Developments, Task 1 : Measurement Method to Verify Wind Turbine Performance Characteristics, Riso National Lab.

  • IEC, 1998,Wind Turbine Generator Systems. Part 12 : Wind Turbine Power Performance Testing, 1st Ed., IEC 61400-12.

  • Lee, J. W. et al., 2002,“The True North Alignment of the Meteorological Mast by Using the Camera,”The 2002 Spring Annual Conference of the Wind Power Technology Research Association.

  • NRG Systems, Inc., 1996, 9300SA Stand Alone Logger : Customer Guide.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoonsu Nam.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nam, Y., Yoo, N. & Lee, J. Site calibration for the wind turbine performance evaluation. KSME International Journal 18, 2250–2257 (2004). https://doi.org/10.1007/BF02990229

Download citation

  • Received:

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02990229

Navigation