Abstract
A combined monitoring and dispersion modelling methodology was applied for assessing air quality at three different levels of proximity to the selected service station: (I) next to the fuel pumps, (II) in the surrounding environment, and (III) in the background. Continuous monitoring and passive sampling were used for achieving high temporal and spatial resolution, respectively. A Gaussian dispersion model (CALINE4) was used for assessing the road traffic contribution to the local concentrations under different meteorological conditions.
It was established that Stage 2 vapour recovery reduces BTX concentrations not only near the pumps, but also in their surrounding environment. However, there is evidence that the efficiency of the system is wind speed dependent. The modelling simulation of the worst case wind scenario revealed the significance of local traffic emissions. It was shown that the traffic contribution even from a single road in the vicinity of the station can, under certain conditions, be higher than the contribution of the station itself to the local BTX levels. Finally, after comparison with previous studies, the concentrations measured near the service station (which was situated in a rural environment) appear to be lower than those observed in busy street canyons in city centres.
It can be concluded, although Stage 2 recovery system effectively reduces working VOC losses in service stations, that it will only have a limited positive impact on local air quality if the service station is located in a heavily polluted area.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
IARC (1987): Monographs Suppl 7, 120–121. International Agency for Research on Cancer (IARC), Lyon, France
WHO (1996): Air quality guidelines for Europe. Regional Publications, European Series. World Health Organization (WHO), Geneva, Switzerland
Commission des Communautes Européennes (1998): Proposition de directive du Conseil concernant les valeurs limites du benzène et du monoxyde de carbone dans l’air ambiant. Bruxelles 1.12/98 COM. 591 final
Loi sur l’air et l’utilisation rationnelle de l’energie. Premier Decret n∘ 98–360 du 6 mai 1998
Directive 94/63/CE du Parlement Européen et du Conseil du 20 déc. 1994 relative à la lutte contre les émissions des composés organiques volatils (COV) resultant du stokage de l’essence et de sa distribution des terminaux aux stations service
Periajo JF, Zambudino A, Prado C (1997): J Chromatogr A, 778, 263–268
Kearney CA, Bunham DB (1986): J Am Ind Hyg Assoc47 (8) 535–539
Bates M; Gonzalez-Flezsca N, Cocheo V, Sokhi R (1997): Analyst122, 1481–1484
Journel AG (1989): American Geophysical Union. Washington DC
Benson PE (1984): Office of Transportation Laboratory. California Department of Transportation. Report 95807. California, USA
Buckland AT, Middleton DR (1999): Nomograms for calculating pollution within street canyons. Atmos Environ33, 1017–1036
Vardoulakis S, Gonzalez-Flesca N, Rouil L, Fisher B (1999): Roadside air quality monitoring and modelling: Canyon street situation. INERIS (France) and University of Greenwich (UK)
Jones G, Gonzalez-Flesca N, Sokhi R, Donald TM, Ma M (1998): Environ Monit Assess52, 107–121
Vardoulakis S, Gonzalez-Flesca N, Fisher B (2000): Monitoring and modelling techniques for assessing air quality in urban micro-environments. INERIS (France) and University of Greenwich
Hartle R (1993): Environ Health Perspect Supplements101 (suppl 6) 23–26
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Gonzalez-Flesca, N., Vardoulakis, S. & Cicolella, A. BTX concentrations near a stage II implemented petrol station. Environ Sci & Potlut Res 9, 169–174 (2002). https://doi.org/10.1007/BF02987484
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02987484