Abstract
Although PCB in caulking materials has been forbidden for many years in most of Europe, including Denmark, there has been continued interest to measure PCB levels in the air of contaminated buildings and blood of the occupants (Mengon and Schlatter 1993, Fromme et al. 1996, Ewers et al. 1998, Currado and Harrad 1998, Gabrio et al. 2000). The relatively low priority for investigations of this contamination is probably due to the small quantities inhaled compared to exposure via food, and the rapid metabolism of the most volatile congeners demonstrated by low concentrations of all congeners in the blood of exposed persons (Ewers et al. 1998, Gabrio et al. 2000). There is, however, evidence that PCB containing caulking materials have been used even during the ’90s (Fromme et al. 1996). In Denmark, it is estimated that 75 t PCB is still in buildings (Organization of Sealant Branch’s Manufacturers and Distributors 2000). During an investigation of dust from buildings with excessive microbial growth (including 35 rooms from 9 buildings), the analysis of semivolatile compounds by thermal desorption-GC/MS of samples from a single building surprisingly revealed large amounts of PCBs containing 3, 4 and 5 chlorine atoms, 10–20 times the amounts found in samples from other buildings. Extraction of the dust by SFE followed by GC/ECD analysis for 12 PCB congeners showed that there was ∼ 20 times the total PCB concentrations in dust from the polluted building compared to the levels in the other buildings. Subsequent headspace analysis of caulking material from the polluted building revealed this to be the source. Shelf dust functions as a passive sampling medium and, thus, can be used as a screening method to detect PCB and other semivolatile pollution indoors.
References
Bøwadt S, Skejø-Andresen H, Montanarella L, Larsen B (1994): HRGC separations of 160 chlorobiphenyls in technical mixtures on four polar narrow-bore columns. Int J Environ Anal Chem56: 87–107
Currado GM, Harrad S (1998): Comparison of polychlorinated biphenyl concentrations in indoor and outdoor air and the potential significance of inhalation as a human exposure pathway. Environ Sci Technol32: 3043–3047
Ewers U, Wittsiepe J, Barth G, Bork M, Kaesler C, Leidel J, Strobel K (1998): Blood tests for PCB in teachers at a heavily PCB-polluted school. Gesundheitswesen60: 357–362
Fromme H, Baldauf AM, Klautke O, Piloty M, Bohrer L (1996): Polychlorinated biphenyls (PCB) in caulking compounds of buildings-assessment of current status in Berlin and new indoor air sources. Gesundheitswesen58: 666–672
Gabrio T, Piechotowski I, Wallenhorst T, Klett M, Cott L, Friebel P, Link B, Schwenk M (2000): PCB-blood levels in teachers, working in PCB-contaminated schools. Chemosphere40: 1055–1062
Mengon W, Schlatter Ch (1993): Polychlorierte Biphenyle (PCB) aus dauerelastistchen Dichtungsstoffen in schweizerischer Innenraumluft. Mitt Gebiete Lebensm84: 250–262
Organization of Sealant Branch’s Manufacturers and Distributors (2000): Inquiry about the use of sealants containing PCB. Copenhagen (in Danish)
Rahman MS, Bøwadt S, Larsen B (1993): Dual-column GC analysis of Mediterranean fish for ten organochlorine pesticides and sixty two chlorobiphenyls. J High Res Chrom16: 731–735
Wilkins K, Nielsen EM, Wolkoff P (1997): Patterns in volatile organic compounds in dust from moldy buildings. Indoor Air7: 128–134
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Wilkins, K., Bøwadt, S., Larsen, K. et al. Detection of indoor PCB contamination by thermal desorption of dust. Environ Sci & Potlut Res 9, 166–168 (2002). https://doi.org/10.1007/BF02987483
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02987483