Abstract
The results of fine needle aspiration biopsy of lymph nodes and subcutaneous masses in 169 patients and the technique used are discussed. Of the 169 cases 76 were classified as cytologically malignant, 52 as benign/inflammatory and 49 as inadequate. Neck masses were most commonly sampled. The overall diagnostic accuracy achieved was 75%. No false positive and 2 false negative cases were seen The advantages and limitations of the procedure are discussed as well as some of the possible sources of error.
Similar content being viewed by others
References
Kline, T. S. Handbook of fine needle aspiration biopsy cytology. Second Edition. Churchill Livingstone, 1988.
Koss, L. G. Aspiration biopsy -a tool in surgical pathology. Amer. J. Surg. Pathol. 1988: 12, 43–53.
Frable, W. J. Fine needle aspiration biopsy. A review. Hum. Pathol. 1983: 14, 9–12.
Ramzy, I., Rone, R., Schultenover, S. J., Buhaug, J. Lymph node aspiration biopsy diagnostic reliability and limitations -An analysis of 350 cases. Diagn. Cytopathol. 1985: 1, 39–45.
Frable, N. J., Kardos, T. F. Fine needle aspiration biopsy. Am. J. Surg. Pathol. 1988: 12, 62–72.
Carter, T. R., Feldman, P. S., Innes, D. J., Frierson, H. F., Frigy, I. F. The role of fine needle aspiration cytology in the diagnosis of lymphoma. Acta Cytol. 1988: 32, 848–853.
Pontifer, A. H., Haley, L. Fine needle aspiration cytology in lymphomas and related disorders. Diagn. Cytopathol. 1989: 5, 432–435.
Qizilbash, A. H., Elavathil, L. J., Chen, V., Young, J. E. M., Stuart, A. D. Aspitation biopsy cytology of lymph nodes in malignant lymphoma. Cytopathol. 1985: 1, 18–22.
Stani, J. Cytologic diagnosis of reactive lymphadenopa-thy in fine needle aspiration biopsy specimens. Acta Cytol. 1987: 31, 8–13.
Dabbs, D. J., Silverman, J. F. Selective use of electron microscopy in fine needle aspiration cytology. Acta Cytol. 1988: 32, 880–884.
Feinmesser, R., Miyazaki, I., Cheung, R., Freeman, J. L., Noyek, A. M., Dosch, H. M. Diagnosis of nasopharyngeal carcinoma by DNA amplification of tissue obtained by fine needle aspiration. NEJM 1992: 326, 17–21.
12. Glaser, K. S., Weger, A. R., Schmidt, K. W., Boder, E. Is fine needle aspiration of tumours harmless? Lancet 1989: 1, 620.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Royston, D. Fine needle aspiration biopsy of lymph nodes and subcutaneous masses. I.J.M.S. 162, 21–23 (1993). https://doi.org/10.1007/BF02942824
Issue Date:
DOI: https://doi.org/10.1007/BF02942824