Sunto
Viene illustrato un modello statistico del rivelatore a scintillazione allo scopo di valutare le imprecisioni nella definizione temporale di eventi nucleari dovuti alla statistica dei processi elementari caratteristici di questorivelatore.
Summary
A statistical model of the scintillation spectrometer is developed. The results are used in order to evaluate the timing inaccuracies in nuclear events detection due to the statistics of physical processes involved.
Similar content being viewed by others
Bibliografia
E. Breitemberger, in Progress in Nuclear Physics4 (ed.O. R. Frisch, Pergamon Press, London 1955).
J. B. Birks,The Theory and Practice of Scintillation Counters (Pergamon Press, London 1964).
E. Gatti eV. Svelto, Nucl. Instr. and Meth.30, 213 (1964).
R. Euling, J. Appl. Phys.35, 1341 (1964).
V. S. Pugachev,Theory of Random Functions (Pergamon Press, Oxford 1965).
A. Bertolaccini, S. Cova, C. Bussolati, S. Donati, V. Svelto, Nucl. Instr. and Meth.51, 325 (1967).
S. Donati, E. Gatti, V. Svelto, Nucl. Instr. and Meth.46, 165 (1967).
Author information
Authors and Affiliations
Additional information
Pervenuta in tipografia il 20 dicembre 1967.
Rights and permissions
About this article
Cite this article
Gatti, E. Analisi statistica del rivelatore a scintillazione. Seminario Mat. e. Fis. di Milano 37, 220–235 (1967). https://doi.org/10.1007/BF02925647
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF02925647