Skip to main content
Log in

Biomechanical finite element analysis of bone cemented hip crack initiation according to stem design

  • Published:
Journal of Mechanical Science and Technology Aims and scope Submit manuscript

Abstract

The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Barsom, J. M. and Rolfe, S. T., 1987,Fracture and Fatigue Control in Structures, 2nd Ed., Prentice-Hall.

  • Bittencourt, T. N., 1993, “Computer Simulation of Linear and Nonlinear Crack Propagation in Cementitious Materials,”Ph D Thesis, Cornell University.

  • Crowninshield, R. D., Brand, R. A., Johnston, R. C. and Milroy, J. C., 1980, “The Effect of Femoral Cross-sectional Geometry on Cement Stresses in Total Hip Reconstruction,”Clinical Orthopedics, Vol. 146, pp. 71–77.

    Google Scholar 

  • Ebramzadeh, E., Sarmiento, A., McKellop, H. A., Llinas, A. and Gogan, W., 1994, “The Cement Mantle in Total Hip Arthroplasty. Analysis of Long-Term Radiographic Results,”Journal of Bone and Joint Surgery, Vol. 76 (A), pp. 77–87.

    Google Scholar 

  • Estok, D.M., Orr, T. E. and Harris, W. H., 1997, “Factors Affecting Cement Strains Near the Tip of a Cemented Femoral Component,”The Journal of Arthroplasty, Vol. 12, No. 1, pp. 40–48.

    Article  Google Scholar 

  • James, J. M. and Ares, J. R., 1993, “On the Dependence of the Dynamic Crack Tip Temperature Fields in Metals Upon Crack Tip Velocity and Material Parameters,”Mechanics of Materials, Vol. 16, No. 4, pp. 337–350.

    Article  Google Scholar 

  • Jasty, M., Maloney, W. J., Bragdon, C. R., Haire, T. and Harris, W. H., 1990, “Histomorphological Studies of the Long-Term Skeletal Responses to well Fixed Cemented Femoral Components,”Journal of Bone Joint Surgery, Vol. 72 (A), pp. 1220–1229.

    Google Scholar 

  • Kawate, K., Maloney, W. J., Bragdon, C. R., Biggs, S.A., Jasty, M. and Harris, W. H., 1998, “Importance of a Thin Cement Mantle. Autopsy Studies of Eight Hips,”Clinical Orthopedic Related Research, Vol. 355, pp. 70–76.

    Article  Google Scholar 

  • Kim, B. S. and Mann, K. A., 1999, “A Thin Cement Mantle Decreases Fatigue Life of Cemented Femoral Hip Component,”Transactions of Orthopaedic Research Society, Vol. 24, pp. 880.

    Google Scholar 

  • Leis, B. N., Hopper, A. T., Broek, J. A. and Kanninen, M. F., 1986, “Critical Review of the Fatigue Growth of Short Cracks,”Engineering Fracture Mechanics, Vol. 23, No. 5, pp. 883–898.

    Article  Google Scholar 

  • Maloney, W., Jasty, M., Rosenburg, A. and Harris, W. H., 1990, “Bone Lysis in Well Fixed Femoral Commponents,”Journal of Bone and Joint Surgery, Vol. 72(B), pp. 966–970.

    Google Scholar 

  • Mann, K. A., Bartel, D. L. and Ayers, D. C., 1997, “Influence of Stem Geometry on Mechanics of Cemented Femoral Hip Components With a Proximal Bond,”Journal of Orthopaedic Research, Vol. 15, No. 5, pp. 700–706.

    Article  Google Scholar 

  • Mann, K. A., Bartel, D. A., Wright, T. M. and Ingraffea, A. R., 1991, “Mechanical Characteristics of the Stem-cement Interface,”Journal of Orthopaedic Research, Vol. 9, pp. 798–808.

    Article  Google Scholar 

  • McCormack, B. A. O., Prendergast, P. J. and Gallagher, D. G., 1996, “An Experimental Study of Damage Accumulation in Cemented Hip Prostheses,”Clinical Biomechanics, Vol. 11, No. 4, pp. 214–219.

    Article  Google Scholar 

  • Mulroy, R. D. and Harris, W. H., 1990, “The Effect of Improved Cementing Techniques on Component Loosening in Total Hip Replacements: an 11-year Radiographic Review,”Journal of Bone and Joint Surgery, Vol. 72(B), pp. 757–760.

    Google Scholar 

  • Rimnac, C. M., Wright, T. M. and McGill, D. L., 1986, “The Effect of Centrifugation on the Fracture Properties of Acrylic Bone Cements,”Journal of Bone and Joint Surgery, Vol. 68 (A), pp. 281–287.

    Google Scholar 

  • Star, M. J., Colwell, C. W., Kelman, G. J., Ballock, R. T. and Walker, R. H., 1994, “Suboptimal (thin) Distal Cement Mantle Thickness as a Contributory Factor in Total Hip Arthroplasty Femoral Component Failure: A Retrospective Radiographic Analysis Favoring Distal Stem Centralization,”The Journal of Arthroplasty, Vol. 9, No. 2, pp. 143–149.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Byungyoung Moon.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, B., Moon, B. & Park, J. Biomechanical finite element analysis of bone cemented hip crack initiation according to stem design. J Mech Sci Technol 20, 2168–2177 (2006). https://doi.org/10.1007/BF02916333

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02916333

Key Words

Navigation