Abstract
With a high-energy resolution micro-X-ray fluorescence (μ-XRF) analysis setup, which basically consists of an X-ray microbeam formed by an X-ray focusing lens combined with an X-ray apparatus and a wavelength dispersive position sensitive spectrometer with a flat crystal (PSS), preliminary results have been obtained. The counting rate of the analyzed element linearly increased with the power of X-ray apparatus, and the energy resolution, full width of half maximum (FWHM) of Kα lines of Ti and Cr reached 16.6 and 23.6 eV, respectively. The Cr Kβ and Mn Kα lines in a sample of stainless steel could clearly be resolved. The above-mentioned results are also compared with those obtained by synchrotron radiation light microbeam combined with the PSS. The facts show that the high-energy resolution element analysis is feasible by using the setup. Moreover, problems for the setup and the ways to resolve them are discussed as well.
Similar content being viewed by others
References
Maeda, K., Hasegawa, K., Hamanaka, H. et al., Development of an in-air high-resolution PIXE system, Nucl. Instr. & Meth., 1998, B134: 418.
Maeda, K., Hasegawa, K., Hamanaka, H. et al., Chemical state analysis in air by high-resolution PIXE, Nucl. Instr. & Meth., 1998, B136–138: 994.
Budnar, M., Kavcic, M., Tadic, T. et al., Use of high-resolution X-ray spectrometer for the study of chemical effects in X-ray spectra. Inter. J. of PIXE, 1996, 6 (1–2): 51.
Cindro, V., Budnat, M., Kregal, M. et al., Double K-shell vacancy production in Ca, Ti, V and Cr bombarded by protons, J. Phys. B: At. Mol. Opt. Phys., 1989, 22: 2161.
Kishimoto, S., Isozumi, Y., Ito, R. et al., A sample crystal spectrometer for low-energy X-rays emission form radio-active source, Appl. Radiat. Isot., 1989, 40(4): 229.
Hu, Z., De Cesare, N., Grassi, D. et al., The energy resolution of a position sensitive spectrometer based on plane crystal, Nucl. Instr. & Meth., 1993, B74: 426.
Maeda, K., Hamanaka, H., Hasegawa, K., High resolution PIXE using crystal spectrometer combined with position-sensitive detectors, Inter. J. of PIXE, 1996. 6 (1-2): 97.
Hu Zhaohui, Nuclear microprobe and position sensitive spectrometer (Chapter 13). Applied Nuclear Spectroscopy (eds. Li Shi et al.) (in Chinese), Beijing: Chinese Science and Technique Press, 1994, 674–722.
Hu Zhaohui. Liu Shijie. Liu Pingsheng et al., High energy resolution position sensitive spectrometer with a flat crystal, High Energy Physics and Nuclear Physics (in Chinese with English abstract), 1999, 23(6): 723.
Watt, F., The nuclear microprobe: A unique instrument, Nuclear Instruments and Methods, 1997, B130: I.
Lce, G. E., Microbeam-forming methods for synchrotron radiation, X-ray Spectrometry, 1997, 26: 315.
Rindy, A., Progress in X-ray microbeam spectroscopy, X-ray Spectrometry, 1993, 22: 187.
Pella, P. A., Lankosz, M., Highlights of X-ray spectrometry for microanalysis, X-ray Spectrometry, 1997. 26: 327.
Mokuno, Y., Horino, Y., Chayahara, A. et al., High energy resolution PIXE with high efficiency using the heavy ion microbeam, Nuclear Instruments and Methods, 1997, B130: 243.
Ding Xunliang, He Yejun, Yan Yiming, X-ray source for X-ray micro-fluorescence using a monolithic X-ray focusing lens combined with aperture optics. X-ray Spectrometry, 1997, 26: 374.
Author information
Authors and Affiliations
About this article
Cite this article
Hu, Z., Liu, S., Liu, P. et al. High-energy resolution μ-XRF analysis by position sensitive spectrometer. Chin.Sci.Bull. 45, 1934–1938 (2000). https://doi.org/10.1007/BF02909681
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02909681