Skip to main content
Log in

A method of extending DPIV and its application in spray droplet size measurements

  • Notes
  • Published:
Chinese Science Bulletin

Abstract

A field method for measuring particle size distribution within a spray was developed based on extending of digital particle image velocimetry (DPIV) in this note. The size distribution of a water mist was successfully measured with this method, and the measured results were compared with the simply calculated ones.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Adrain, R. J., Particle-image techniques for experimental fluid mechanics, Annu. Rev. Fluid Mech., 1991, 23: 261.

    Article  Google Scholar 

  2. Weng Wenguo, Liao Guangxuan, Wang Xishi, Study on the diagnostic method (DPIV) based on cross-correlation, Experiments Mechanics (in Chinese), 1999, 14(3): 1.

    Google Scholar 

  3. Willert, C. E., Gharib, M., Digital particle image velocimetry, Exp. Fluids, 1991, 10: 181.

    Article  Google Scholar 

  4. Prasad, A. K., Adrain, R. J., Stereoscopic particle image velocimetry applied to liquid flows, Experiments in Fluids, 1993, 15: 49.

    Article  CAS  Google Scholar 

  5. Willert, C., Stereoscopic digital particle image velocimetry for application in wind tunnel flows, Meas. Sci. Technol. 1997, 8: 1465.

    Article  Google Scholar 

  6. Huang, H., Dabiri, D., Gharib, M. et al., On errors of digital particle image velocimetry, Meas. Sci. & Technol., 1997, 8: 1427.

    Article  CAS  Google Scholar 

  7. Boyaval, S., Dumouchel, C., Experimental investigation on the measurement of drop size distribution of sprays produced by high pressure swirl atomizers, 8th International Conference on Liquid and Spray Systems (CD-edition), California: Pasadena, USA, 2000, 147–154.

  8. Sharief, R. A., Steady state high pressure spray cooling of high temperature steel surfaces, 8th International Conference on Liquid and Spray Systems, California: Pasadena, USA, 2000, 392–399.

  9. Wang Xishi, Liao Guangxuan, Yao Bin et al., Preliminary study on the interaction of water mist with pool fires, J. of Fire Sciences, 2001, 19: 1.

    Google Scholar 

  10. Bachalo, W. D., Spray diagnostics for the 21 century, Atomization and Sprays, 2000, 10: 439.

    Google Scholar 

  11. Mawhinney, J. R., Vollman, C. L. Anderson, R. et al., NFPA 750 Standard on Water Mist Fire Protection Systems, 1996, 750–755.

  12. Wu Jiankang, Digital Image Processing (in Chinese), Beijing: People’s Posts & Telecommunications Publishing House, 1989.

    Google Scholar 

  13. Cui Yi, Image Processing and Analysis—Mathematical Morphologic Methods and its Application, Beijing: Science Press, 2000.

    Google Scholar 

  14. Chow, W. K., Yin, R. M., Review of droplet size distributions for a water spray, Applied Fire Science, 1998, 7: 180.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xishi Wang.

About this article

Cite this article

Wang, X., Wu, X. & Liao, G. A method of extending DPIV and its application in spray droplet size measurements. Chin. Sci. Bull. 47, 1045–1049 (2002). https://doi.org/10.1007/BF02907580

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02907580

Keywords

Navigation