A silicon ion-implanted strip detector for position and energy loss measurements

Кремниевый детектор для измерения положения и энергетических потерь ионизирующей частицы

  • Published:
Il Nuovo Cimento A (1965-1970)

Summary

A prototype of silicon ion-implanted strip detector is described: the device is composed by twelve 4 mm×50 mm strips connected to fast charge-sensitive preamplifiers so that both energy loss and position of an ionizing particle can be measured. The detector performances, determined in laboratory tests and in a photodisintegration experiment, are also reported.

Riassunto

Si descrive un rivelatore a strip di silicio del tipo ad impiantazione ionica. Tale prototipo è composto da 12 strip di 4 mm×50 mm ed è connesso a preamplificatori veloci in carica, in modo da misurare sia la posizione che la perdita di energia delle particelle ionizzanti. Si riportano, inoltre, le prestazioni del rivelatore sia in laboratorio che in un esperimento di fotodisintegrazione.

Резюме

Описывается прототип кремниевого детектора. Прибор состоит из двенадцати пластин 4 мм×50 мм, соединенных с предусилителями, так что могут быть измерены положение и энергетические потери ионизирующей частицы. Приводятся результаты испытаний детектора в лабораторных условиях и в эксперименте по фоторасщеплению.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. M. McKenzie:Nucl. Instrum. Methods,162, 49 (1979).

    Article  ADS  Google Scholar 

  2. P. Doll, G. Fink, F. Brady, R. Garrett, H. O. Klages andH. Krupp:Nucl. Instrum. Methods A,250, 526 (1986).

    Article  ADS  Google Scholar 

  3. E. Heijne, L. Hubbeling, B. Hyams, P. Jarron, P. Lazeyras, F. Piuz, J. Vermeulen andA. Wylie:Nucl. Instrum. Methods,178, 331 (1980).

    Article  ADS  Google Scholar 

  4. J. Kemmer, P. Burger, R. Henck andE. Heijne:IEEE Trans. Nucl. Sci., NS-29, 1 (1982).

    Article  Google Scholar 

  5. F. Goulding andD. Landis:IEEE Trans. Nucl. Sci., NS-29, 1125 (1982).

    Article  ADS  Google Scholar 

  6. Laben industries (Milan).

  7. E. Durante, M. Sanzone andA. Zucchiatti:Nucl. Instrum. Methods,129, 467 (1975).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Переведено редакцией.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Anghinolfi, M., Castoldi, M. & Rottura, A. A silicon ion-implanted strip detector for position and energy loss measurements. Nuov Cim A 98, 551–558 (1987). https://doi.org/10.1007/BF02902012

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02902012