Skip to main content
Log in

Evaluation of an automatic fogging disinfection unit

  • Original Article
  • Published:
Environmental Health and Preventive Medicine Aims and scope

Abstract

A new fogging disinfection method was evaluated as a means of disinfecting ward rooms and operating theaters. A temporary room was established where the disinfection effect of fogging was examined. Based on the results, an automatic fogging disinfection unit was developed. This unit was then used in the disinfection of operating theaters, where its safety and effectiveness were examined.

To evaluate the results of disinfection, bacterial culture tests were performed on the floor, walls and other areas of the operating theater, and the number of colony forming units was used as an index of effectiveness. Benzalkonium chloride, alkyldiaminoethylglycine, sodium hypochlorite, glutaral and acidic electrolytic water were used for the operating theaters. The average disinfection effect was 90% or better for all disinfectants, except acidic electrolytic water.

The newly developed automatic fogging disinfection unit enables safe and effective disinfection, and may be suitable for disinfecting ward rooms and operating theaters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. AORN. Proposed recommended practices. Operating room environmental sanitation. AORN J. 1988; 48: 332–340.

    Article  Google Scholar 

  2. AORN. Proposed recommended practices. Sanitation in the surgical practice setting. AORN J. 1991; 54: 1251–1257.

    Article  Google Scholar 

  3. Pryor AK. Optimizing operating room cleaning results. AORN J. 1972; 15: 95–109.

    Article  PubMed  CAS  Google Scholar 

  4. Vesley D, Pryor AK, Walter WG, Shaffer JG. A cooperative microbiological evaluation of floor-cleaning procedures in hospital patient room. Health. Lab. Sci. 1970; 7: 256–264.

    PubMed  CAS  Google Scholar 

  5. U.S. Department of Health and Human Services. Guidelines for the prevention and control of nosocomial infection. Guideline for hospital environmental control. Guidelines, Nosocomial Infections by Center for Disease Control, Atlanta, U.S.A., 1981, p. 1–2.

    Google Scholar 

  6. CDC guidelines for the prevention and control of nosocomial infections. Guideline for hand washing and hospital environmental control, 1985. Supersedes guideline for hospital environmental control published in 1981. Am. J. Infect. Control. 1986; 14: 110–129.

    Google Scholar 

  7. Mangram AAJ, Horan TC, Pearson ML, et al. HICPAC; Guidline for prevention of surgical site infection. Infect Control Hosp Epidemiol 1999; 20: 247–278.

    Article  Google Scholar 

  8. Jono K, Takayama T, Kuno M, Higashide E. Effect of alkyl chain length of benzalkonium chloride on the bactericidal activity and binding to organic materials. Chem. Pharm. Bull. 1986; 34: 4215–4224.

    PubMed  CAS  Google Scholar 

  9. Rutala WA. APIC guidelines for infection control practice, APIC guideline for selection and use of disinfection. Am. J. Infect. Control. 1990; 18: 99–117.

    Article  PubMed  CAS  Google Scholar 

  10. Rutala WA, Weber DJ. Infection control: the role of disinfection and sterilization. J. Hosp. Infect. 1999; 43(Suppl): S43–55.

    Article  PubMed  Google Scholar 

  11. Suzuki A, Namba Y, Matsuura M, Horisawa A. Bacterial contamination of floors and other surfaces in operating rooms: a five-year survey. J. Hyg. Camb. 1984; 93: 559–566.

    Article  PubMed  CAS  Google Scholar 

  12. Pryor AK, Vesley, D, Shafler JG, et al. Cooperative microbial surveys of surfaces in hospital patient rooms. Health. Lab. Sci. 1967; 4: 153–159.

    PubMed  CAS  Google Scholar 

  13. Kuipers JS. Investigation and treatment of floors of patients' rooms: a study with an agar cylinder. J. Hyg. 1968; 66: 625–631.

    CAS  Google Scholar 

  14. Suzuki A, Namba Y, Matsuura M, Horisawa A. Airborne contamination in an operating suite: report of a five-year survey. J. Hyg. 1984; 93: 567–573.

    CAS  Google Scholar 

  15. AORN. Recommended practices. Sanitation in the surgical practice setting. AORN J. 1992; 56: 1089–1095.

    Article  Google Scholar 

  16. Rutala, WA. Disinfection in the OR. Today's OR Nurse. 1990; 12: 30–38.

    CAS  Google Scholar 

  17. Garner JS, Favero MS. CDC guidelines for the prevention and control of nosocomial infections: Guideline for hand washing and hospital environmental control, 1985. Am. J. Infect. Control. 1986; 14: 110–126.

    Article  PubMed  CAS  Google Scholar 

  18. Garner JS, Favero MS. Proposed recommended practices. Operating room environmental sanitation. AORN Recommended Practices Subcommittee of the TPCC. AORN J. 1988; 48: 332–336.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Seizoh Nakata.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nakata, S., Ikeda, T., Nakatani, H. et al. Evaluation of an automatic fogging disinfection unit. Environ Health Prev Med 6, 160–164 (2001). https://doi.org/10.1007/BF02897964

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02897964

Key words

Navigation