Skip to main content
Log in

Clinical application of surface mode on three-dimensional ultrasonography: A preliminary study

  • Published:
Current Medical Science Aims and scope Submit manuscript

Summary

To investigate the methodology and evaluate the clinical value of surface mode on three-dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipment used here was Voluson 530D 3DUS imaging system and 3D volume transducer with frequency being 3.0—5.0 MHz. The 3DUS rendering method was surface mode. The results showed that: 1) Surface mode of 3DUS could demonstrate clearly the anatomical characteristics of the region-of-interest (ROD and the inner wall of lesions or organs that contained fluid. The anatomic details, such as location, size, shape, and number of the ROI, could be visualized intuitively; 2) The outer anatomic features (e.g. contour, edge, configuration, etc.) of some organs or lesions surrounded by fluid could be displayed clearly. It could be concluded that surface mode on 3DUS could provide more diagnostic information than two-dimensional ultrasonography (2DUS) in some cases and could served as a beneficial supplement to 2DUS in clinical practice.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Referances

  1. Rankin R N, Fenster A, Downey D Bet al. Three-dimensional sonographic reconstruction: techniques and diagnostic applications. AJR, 1993, 161:695

    Article  CAS  PubMed  Google Scholar 

  2. Downey D B, Fenster A. Vascular imaging with a three-dimensional power Doppler system. AJR, 1995, 165:665

    Article  CAS  PubMed  Google Scholar 

  3. Hamper U M, Trapanotto V, Sheth Set al. Three-dimensional US: preliminary clinical experience. Radiology, 1994, 191:397

    Article  CAS  PubMed  Google Scholar 

  4. 1998,7(1):3

  5. 1999,8(2):8

  6. 1999,15(6):412

  7. Xu H X, Zhang Q P, Zhou Y Q. The clinical application of three-dimensional sonography in hepatobiliary diseases. J CAUME, 1999, 5(2):61

    Google Scholar 

  8. Nelson T R, Pretorius D H. Three-dimensional ultra-sound imaging. Ultrasound Med Biol, 1998, 24(9):1243

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Huixiong, X., Qingping, Z., Yuqing, Z. et al. Clinical application of surface mode on three-dimensional ultrasonography: A preliminary study. Current Medical Science 20, 159–162 (2000). https://doi.org/10.1007/BF02887061

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02887061

Key words

Navigation