Skip to main content
Log in

An on-line TDC-312 computer-controlled neutron diffractometer

  • Experimental Techniques And Instrumentation
  • Published:
Pramana Aims and scope Submit manuscript

Abstract

The design and fabrication of an indigenous on-line computer controlled four-circle neutron diffractometer at the CIRUS reactor in Trombay are described. The diffractometer has an 18 in dia full-circle crystal-orienter which is sturdy enough to carry a cryostat. Three crystal orientation angles χ, φ and ω and the detector angle 2θ can be set to an accuracy of 0·01°. The four angle shafts are driven through precision worm-gears by SCR-controlled DC motors and their instantaneous positions sensed by optical digitizers. The diffractometer is interfaced to an ECIL TDC-312 computer system consisting of the CPU with 4K-memory, ASR-35 teletype, X-Y plotter and the digital input/output system (DIOS). The DIOS which operates under program control is a real-time peripheral device used to exchange information in digital form between the computer and the diffractometer. A software package consisting of over 40 useroriented teletype commands has been developed for on-line control and automatic data-acquisition.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Arndt U W and Willis B T M 1966Single Crystal Diffractometry (London: Cambridge University Press)

    Google Scholar 

  • Arndt U W, Willis B T M and Causer R 1962 Report No. AERE-4143 (Atomic Energy Research Establishment, Harwell)

  • Busing W R, Ellison R D, Levy H A, King S P and Roseberry R T 1968 Report No. ORNL-4143 (Oak Ridge National Laboratory, Oak Ridge)

  • Busing W R and Levy H A 1967Acta Cryst. 32 457

    Article  Google Scholar 

  • Coppens P and Hamilton W C 1970Acta Cryst. A26 71

    Google Scholar 

  • Momin S N, Sequeira A and Chidambaram R 1974Indian J. Pure Appl. Phys. 12 121

    Google Scholar 

  • Willoughby T V, Marimoto C N, Sparks R A and Meyer E F 1974J. Appl. Cryst. 7 430

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sequeira, A., Momin, S.N., Rajagopal, H. et al. An on-line TDC-312 computer-controlled neutron diffractometer. Pramana - J. Phys. 10, 289–302 (1978). https://doi.org/10.1007/BF02872027

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02872027

Keywords

Navigation