Abstract
A sensitive and simplified HPLC assay of fluconazol is described. The calibration curve of fluconazol in plasma ranging 0–10 μ g/ml was linear with the correlation coefficients of 0.9900. The limit of detection was 0.3 μ g/ml. The average recovery of the drug was 89.1±9.05%. After oral administration of single dose(150mg) of fluconazol in man, Cmax and Tmax were 3 μg/ml and 4hr., respectively.
Similar content being viewed by others
Literature Cited
Troke, P.F., Andrews, R.J., Brammer, K.W., Marriott, M.S. and Richardson, K.: The activity of UK-49858 in several animal models of infection. 1Xth Int. Cong. Int. Soc. Human Anim. Mycol. abstr. R2-7 (1985).
Humphrey, M.J., Jevons, S. and Tarbit, M.H.: Pharmacokinetic Evaluation of UK-49858, a metabolically stable Triazole antifungal drug, In Animals and Humans.Antimicrob. Agents Chemother. 28, 648 (1985).
Analysis of Fluconazol in Human Plasma using an automated HPLC method. Pfizer Central Research, Department of drug metabolism, 1986 (Unpublished Information).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kim, E.J., Lee, H.S., Zee, O.P. et al. A sensitive and simplified HPLC analysis for the determination of fluconazol in human plasma. Arch. Pharm. Res. 11, 250–252 (1988). https://doi.org/10.1007/BF02861318
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02861318