Abstract

The development of a neutron moisture gauge, using Cf252 as a source of fast neutrons and muscovite as a detector of thermal-neutron-induced-fission in Pu239 target, is reported. The laboratory and the field calibrations of the instrument reveal a linear relation between track count rate and the moisture volume fraction.

Low cost, low weight, simplicity of operation, thermal stability and elimination of electronic gadgets and power supplies are the attractive features of this instrument. The main drawback is its poor detection efficiency for thermal neutrons and the consequent unsuitability as a routine logging instrument. Its special features make it particularly suited to deep bore hole logging such as in oil exploration.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bell J P and McCulloch J S G 1969J. Hydrol 7 415

    Article  Google Scholar 

  • Cotechia V, Inzabhi A, Pirastru E and Richheva R 1968Water Resour. Res. 4 (No. 5) 1023

    Article  ADS  Google Scholar 

  • Fleischer R L, Price P B, and Walker R M 1965 Solid State Track Detectors, Applications to Nuclear Science and GeophysicsAnnu. Rev. Nucl. Sci. 15

  • International Atomic Energy Agency, Vienna 1970 Neutron Moisture Gauges, Technical Reports Series No. 112

  • Mehta P P and Rama 1969Earth Planet. Sci. Lett. 7 82

    Article  ADS  Google Scholar 

  • Nichols Jere P 1968Nucl. Appl. 4 382

    Google Scholar 

  • Olgaard P L 1965 Danish Atomic Energy Commission, Riso Report 97

  • Price P B and Walker R M 1963J. Geophys. Res. 68 4847

    ADS  Google Scholar 

  • Rama 1966Neutron moisture logging camera, paper presented at the first meeting of the Working Group of Nuclear Techniques in Hydrology, I A E A Vienna

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nagpal, M.K., Mehta, P.P., Nagpaul, K.K. et al. Characteristics of a neutron moisture gauge with a solid state detector. Pramana - J. Phys. 1, 112–116 (1973). https://doi.org/10.1007/BF02847186

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02847186

Keywords

Navigation