Abstract
In near-infrared (NIR) analysis of plant extracts, excessive background often exists in near-infrared spectra. The detection of active constitutents is difficult because of excessive background, and correction of this problem remains difficult. In this work, the orthogonal signal correction (OSC) method was used to correct excessive background. The method was also compared with several classical background correction methods, such as offset correction, multiplicative scatter correction (MSC), standard normal variate (SNV) transformation, de-trending (DT), first derivative, second derivative and wavelet methods. A simulated dataset and a real NIR spectral dataset were used to test the efficiency of different background correction methods. The results showed that OSC is the only effective method for correcting excessive background.
Similar content being viewed by others
References
Alsberg, B.K., Woodward, A.M., Kell, D.B., 1997. An introduction to wavelet transforms for chemometricians: A time-frequency approach.Chemometrics and Intelligent Laboratory Systems,37:215–239.
Andersson, C.A., 1999. Direct orthogonalization.Chemometrics and Intelligent Laboratory Systems,47:51–63.
Barclay, V.J., Bonner, R.F., 1997. Application of wavelet transforms to experimental spectra: Smoothing, denosing, and data set compression.Analytical Chemistry,69:78–90.
Barnes, R.J., Dhanoa, M.S., Lister, S.J., 1989. Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra.Applied Spectroscopy,43:772–777.
Brereton, R.G., 2003. Chemometrics: Data Analysis for the Laboratory and Chemical Plant. John & Wiley, Chichester, England, p.123.
Brindle, J.T., Nicholson, J.K., Schofield, P.M., Grainger, D.J., Holmes, E., 2003. Application of chemometrics to H-1 NMR spectroscopic data to investigate a relationship between human serum metabolic profiles and hypertension.Analyst,128:32–36.
Candolfi, A., Maesschalck, R.D., Jouan-Rimbaud, D., Hailey, P.A., Massart, D.L., 1999. The influence of data pre-processing in the pattern recognition of excipients near-infrared spectra.Journal of Pharmaceutical and Biomedical Analysis,21:115–132.
Fearn, T., 2000. On orthogonal signal correction.Chemometrics and Intelligent Laboratory Systems,50:47–52.
Geladi, P., MacDougall, D., Martens, H., 1985. Linearization and scatter-correction for near-infrared reflectance spectra of meat.Applied Spectroscopy,39:491–500.
Karstang, T.V., Kvalheim, K., 1991. Multivariate prediction and background correction using local modelling and derivative spectroscopy.Analytical Chemistry,63:767–772.
Ma, X.G., Zhang, Z.X., 2003. Application of wavelet transform to background correction in inductively coupled plasma atomic emission spectrometry.Analytica Chimica Acta,485:233–239.
Mittermayr, C.R., Tan, H.W., Brown, S.D., 2001. Robust calibration with respect to background variation.Applied Spectroscopy,55:827–833.
Peussa, M., Harkonen, S., Puputti, J., Niinisto, L., 2000. Application of PLS multivariate calibration for the determination of the hydroxyl group content in calcined silica by DRIFTS.Journal of Chemometrics,14:501–512.
Schechter, I., 1995. Correction for nonlinear fluctuating background in monovariable analytical systems.Analytical Chemistry,67:2580–2585.
Sjoblom, J., Svensson, O., Josefson, M., Kullberg, H., Wold, S., 1998. An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra.Chemometrics and Intelligent Laboratory Systems,44:229–244.
Sun, J.G., 1997. Statistical analysis of NIR data: Data pretreatment.Journal of Chemometrics,11:525–532.
Tahboub, Y.R., Pardue, H.L., 1985. Evaluation of multiwavelength first- and second-derivative spectra for the quantitation of mixtures of polynuclear aromatic hydrocarbons.Analytical Chemistry,57:38–41.
Tan, H.W., Brown, S.D., 2002. Wavelet analysis applied to removing non-constant, varying spectroscopic background in multivariate calibration.Journal of Chemometrics,16:228–240.
Trygg, J., Wold, S., 2002. Orthogonal projections to latent structures (O-PLS).Journal of Chemometrics,16:119–128.
Westerhuis, J.A., de Jong, S., Smilde, A.K., 2001. Direct orthogonal signal correction.Chemometrics and Intelligent Laboratory Systems,56:13–25.
Wold, S., Antti, H., Lindgren, F., Ohman, J., 1998. Orthogonal signal correction of near-infrared spectra.Chemometrics and Intelligent Laboratory Systems,44:175–185.
Yang, N.L., Cheng, Y.Y., Qu, H.B., 2003. A new method for process analysis of purification of natural herb using NIRS.Acta Chimica Sinica,61:742–747.
Author information
Authors and Affiliations
Corresponding author
Additional information
Project supported by the Zhejiang Province Key Technologies R & D Program (No. 021103549) and the National Key Technologies R & D Program (No. 2001BA701A45), China
Rights and permissions
About this article
Cite this article
Hai-bin, Q., Dan-lin, O. & Yi-yu, C. Background correction in near-infrared spectra of plant extracts by orthogonal signal correction. J. Zheijang Univ.-Sci. B 6, 838–843 (2005). https://doi.org/10.1007/BF02842446
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02842446