Abstract
This study purposed to develop experiment-based limiting heights for interior, non-load bearing, cold-formed steel wall panels subjected to uniformly distributed lateral loadings. The composite panel of this study consists of three C-section steel wall studs with gypsum wallboard attached to each flanges of the stud with screws at regular intervals. The limiting heights were evaluated by their deflection and strength (for flexure, shear, and web crippling). Limiting heights for deflection limits ofL/360,L/240, andL/120 (whereL is the height of the wall) were developed over the range of typical design pressures. The experimental results for nominal 0.02in thickness and 12in stud spacings showed limiting heights increases from 6% to 18% compared to the current SSMA tables. Therefore, the procedure used by the SSMA for 12in spacing is conservative in this range.
Similar content being viewed by others
References
American Society for Testing Materials (ASTM) (2000). “Standard Methods of Conducting Strength Tests of Panels for Building Construction.” E 72–98,Annual Book of Standards, West Conshohocken, PA.
International Conference of Building Officials Evaluation Service, Inc. (ICBO ES) (1996).Acceptance Criteria for Determining Limiting Heights of Composite Walls Constructed of Gypsum Board and Steel Studs (AC86), Whittier, CA.
International Conference of Building Officials (ICBO) (1997).Uniform Building Code, Vol. 2. Structural Engineering Design Provisions, Whittier, CA.
Lee, Y.K. and Miller, T.H. (1997).Final Report on Composite Wall Tests, Department of Civil Engineering, Oregon State University, Corvallis, OR.
Yu, W.W. (2000).Cold-Formed Steel Design, 3rd edition. John Wiley & Sons, New York, N.Y.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Choi, H., Lee, Yk. Testing of cold-formed steel wall stud panels. KSCE J Civ Eng 8, 59–64 (2004). https://doi.org/10.1007/BF02829081
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02829081