The capability of PIXE analysis to simultaneously detect trace elements with Z≥14, with a high power of detection, can be exploited in biomedical research if the diameter of the proton beam is reduced to micrometer dimensions. In this case, trace analyses of small particles or small parts of a larger specimen are rendered possible without deteriorating the detection limits of PIXE. The measurements yield a completely new type of information on the biological microstructure. In order to fully utilize the abilities of the combined method, however, sample preparation techniques, and irradiation procedures have to be adapted to each analysis problem. Examples of application of the Bochum Proton Microprobe will be used to demonstrate how and to what extent this can be achieved for different types of biomedical problems.
Similar content being viewed by others
References
T. B. Johansson, R. Akselsson, and S. A. E. Johansson,Nucl. Instr. and Meth. 84, 141 (1970).
Proc. Int. Conf. on Particle Induced X-Ray Emission and its Analytical Applications,Nucl. Instr. and Meth. 142, (1977).
Proc. Second Int. Conf. on Particle Induced X-Ray Emission and its Analytical Applications,Nucl. Instr. and Meth. 181 (1981).
Proc. Third Int. Conf. on PIXE and its Analytical Applications,Nucl. Instr. and Meth. B3 (1984).
B. Gonsior and M. Roth,Talanta 30, 385 (1983).
J. A. Cookson,Nucl. Instr. and Meth. 181, 115 (1981), and other references therein.
G. J. F. Legge,Nucl. Instr. and Meth. B3, 561 (1984), and other references therein.
H. R. Wilde, M. Roth, C. D. Uhlhorn, and B. Gonsior,Nucl. Instr. and Meth. 149, 675 (1978).
W. Lindh, D. Brune, G. Nordberg, and P. O. Wester,Sci. Total Environ. 16, 109 (1980).
W. Maenhaut, L. de Reu, H. A. van Rinsvelt, J. Cafmeyer, and J. van Espen,Nucl. Instr. and Meth. 168, 557 (1980).
H. R. Wilde, W. Bischof, B. Raith, C. D. Uhlhorn and B. Gonsior,Nucl. Instr. and Meth. 181, 165 (1981).
M. Höfert, W. Bischof, A. Stratmann, B. Raith, and B. Gonsior,Nucl. Instr. and Meth. B3, 572 (1984).
H. Puxbaum,Fresenius Z. Anal. Chem. 298, 110 (1979).
H. Koyama-Ito, E. Wada, T. Tsumita, M. Horiuchi, and S. Iwata,Nucl. Instr. and Meth. B3, 625 (1984).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Gonsior, B., Bischof, W., Höfert, M. et al. Application of a proton microprobe to biomedical research. Biol Trace Elem Res 12, 33–44 (1987). https://doi.org/10.1007/BF02796664
Issue Date: