Skip to main content
Log in

Reliability of the ICP-AES for trace elements studies of biological materials

  • Techniques
  • Published:
Biological Trace Element Research Aims and scope Submit manuscript

Abstract

In order to investigate the reliability of the Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) for trace element analysis of biological materials, we have carried out extensive investigations on human plasma, using an Applied Research Laboratory’s ICP-AES. When we aspirated the untreated plasma into the spectrometer, we obtained unreliable and nonreproducible results. However, when we pretreated the plasma by wet digestion (to destroy all the organic material), we achieved reproducible and consistent results. It is, therefore, suggested that biological samples should be pretreated, preferably by wet digestion, before being aspirated into the ICP-AES for analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. W. J. Haas and V. A. Fassel,Elemental Analysis of Biological Materials, Technical Report Series No. 197, Int. Atomic Energy Agency, Vienna, 1979, pp. 167.

    Google Scholar 

  2. N. R. McQuaker, P. D. Kluckner, and G. N. Chang,Anal. Chem. 51, 888 (1979).

    Article  CAS  Google Scholar 

  3. V. A. Fassel and R. N. Knisely,Anal. Chem. 46, 115A (1974).

    Google Scholar 

  4. S. Greenfield, H. McD. McGeachin, and P. B. Smith,Talanta 22, 1 (1975);Talanta 22, 553 (1975); andTalanta 23, I (1976).

    CAS  Google Scholar 

  5. G. V. Iyengar, Private Communications.

  6. R. D. Irons, E. A. Shenk, and D. A. Giaque,Clin. Chem. 22, 2018 (1976).

    PubMed  CAS  Google Scholar 

  7. R. L. Dahlquist and J. W. Knoll,Appl. Spectrosc. 32, 1 (1978).

    Article  CAS  Google Scholar 

  8. F. N. Abercrombie, M. D. Silvester, and R. B. Cruz,Adv. Chem. Ser. 172, 10 (1979).

    Article  CAS  Google Scholar 

  9. F. E. Lichte, S. Hopper, and T. W. Osborn,Anal. Chem. 52, 120 (1980).

    Article  PubMed  CAS  Google Scholar 

  10. K. S. Subramanian and J. C. Meranger,Sci. Total Environ. 24, 147 (1982).

    Article  PubMed  CAS  Google Scholar 

  11. C. O. Hershey, L. A. Hershey, A. Varnes, S. D. Vibhaker, P. Lavin, and W. H. Strain,Neurology 33, 1350 (1983).

    PubMed  CAS  Google Scholar 

  12. W. M. Blakemore, P. H. Casey, and W. R. Collie,Anal. Chem. 56, 1376 (1984).

    Article  PubMed  CAS  Google Scholar 

  13. C. W. McLeod, P. J. Worsfold, and A. G. Cox,Analyst 109, 327 (1984).

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chaudhri, M.A., Hannaker, P. Reliability of the ICP-AES for trace elements studies of biological materials. Biol Trace Elem Res 13, 417–421 (1987). https://doi.org/10.1007/BF02796652

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02796652

Index Entries

Navigation