Abstract
Because of the large μ mass compared to the electron mass, the muonic X-rays have energies very suitable for standard γ-ray spectroscopy (Ge detectors), so every element is easily recognized. By selecting the primary μ energies appropriately any part of the specimen, also well inside, can be nondestructively investigated. On the other hand, surface layers may be analyzed. Accuracies of quantitative analyses are 1% of the atomic abundance of the element in question in favorite cases. Results on applications in nuclear medicine and surface physics are presented, and ways of improving the muon flux density are discussed.
Similar content being viewed by others
References
Precise values are found inParticle Data Group, C. G. Wohl, R. N. Cahn, A. Rittenberg, T. G. Trippe, G. P. Yost, F. C. Porter, J. J. Hernandez, L. Montanet, R. E. Hendrick, R. L. Crawford, M. Roos, N. A. Törnqvist, G. Höhler, M. Aguilar-Benitez, T. Shimada, M. J. Losty, G. P. Gopal, Ch. Walck, R. E. Shrock, R. Frosch, L. D. Roper, W. P. Trower, and B. Armstrong,Rev. Mod. Phys. 56, S 1 (1984).
H. Daniel,Nucl. Med. 8, 311 (1969).
SIN User’s Handbook, SIN, Villigen, Switzerland, 1981.
H. Daniel,Z. Phys. A313, 249 (1983); H. Daniel,Concentration of Charged Particles with the help of a Moderator in a Magnetic Bottle, LA-UR 84-3248, Los Alamos National Laboratory, Los Alamos, NM, 1984.
D. Taqqu,Phase Space Compression of Muon Beams, TM-30-25, SIN, Villigen, Switzerland, 1984.
E. Fermi and E. Teller,Phys. Rev. 72, 399 (1974).
G. Fottner, H. Daniel, P. Ehrhart, H. Hagn, F. J. Hartmann, E. Köhler, and W. Neumann,Z. Phys. A304, 333 (1982).
H. Daniel, G. Fottner, H. Hagn, F. J. Hartmann, P. Stoeckel, and W. Wilhelm,Phys. Rev. Lett. 46, 720 (1981).
Munich group, unpublished.
H. Daniel, Radiat. Eff.28, 189 (1976).
H. Daniel,Ann. Phys. (NY)129, 303 (1980).
N. A. Cherepkov and L. V. Chernysheva,Sov. J. Nucl. Phys. 32, 366 (1980).
J. S. Cohen, R. L. Martin, and W. R. Wadt,Phys. Rev. A24, 33 (1981); J. S. Cohen, R. L. Martin, and W. R. Wadt,Phys. Rev. A27, 1821 (1983).
R. Callies, H. Daniel, F. J. Hartmann, and W. Neumann,Phys. Lett. A91, 441 (1982).
F. J. Hartmann, T. von Egidy, R. Bergmann, M. Kleber, H.-J. Pfeiffer, K. Springer, and H. Daniel,Phys. Rev. Lett. 37, 331 (1976).
H. Daniel, J. Reidy, R. Hutson, J. Bradbury, and J. Helland,Radiat. Res. 68, 171 (1976).
H. Daniel, F. J. Hartmann, and E. Köhler,Fresenius’ Z. Anal. Chemie 321, 65 (1985).
J. J. Reidy, R. L. Hutson, H. Daniel, and K. Springer,Anal. Chem. 50, 40 (1978).
H. Daniel, H.-J. Pfeiffer, and K. Springer,Biomed. Tech. 18, 222 (1973).
H. Daniel, H.-J. Pfeiffer, and K. Springer,Phys. Med. Biol. 20, 1035 (1975).
R. L. Hutson, J. J. Reidy, K. Springer, H. Daniel, and H. B. Knowles,Radiology 120, 193 (1976).
H. Daniel, F. J. Hartmann, E. Köhler, V. Beitat, and J. Kiederer, to appear inArchaeometry.
E. Köhler, R. Bergmann, H. Daniel, P. Ehrhart, and F. J. Hartmann,Nucl. Instr. Meth. 187, 563 (1981).
S. van der Meer,Stochastic Damping of Betatron Oscillations in the ISR, CERN-ISR-PO/72-31, CERN, Geneva, Switzerland, 1972.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Daniel, H. Application of muonic X-rays for elemental analysis. Biol Trace Elem Res 13, 301–318 (1987). https://doi.org/10.1007/BF02796642
Issue Date:
DOI: https://doi.org/10.1007/BF02796642