Abstract
Enriched fecal and urine samples were prepared using ion-exchange column chromatography for analysis by Inductively Coupled and Fast Atom Bombardment Mass spectrometry (ICP-MS, FAB-MS) to compare precision between methods. Unenriched samples of human milk, feces, and whole blood were prepared similarly to monitor instrumental precision and analytical error. A least squares fit of the ICP-MS results vs the FAB-MS for70Zn/64Zn gave a slope of 0.98, with a relative standard deviation (RSD) of only 0.7%. The results for68Zn/64Zn gave a slope of 0.82, with a RSD of 14%. For unenriched tissues, all potential interferences were removed by the preparation procedure with no significant differences between preparation for isotope ratios of70Zn/64Zn,68Zn/64Zn,67Zn/64Zn, and66Zn/64Zn. Poisson counting statistics are a major contribution to the total analytical error indicating the usefulness of this procedure for enrichment studies.
Similar content being viewed by others
References
K. M. Hambidge, C. E. Casey, and N. F. Krebs Zinc. inTrace Elements in Human and Animal Nutrition, W. Mertz, ed, Academic Press, Orlando, FL, 1986,2 Ch. 1.
N. W. Solomons,Am. J. Clin. Nutr. 32(12), 856 (1979).
M. Janghorbani,Prog. Food Nutr. Sci. 8, 303 (1984).
E. E. Ziegler, R. S. Serfass, S. E. Nelson, R. F. Colon, B. E. Edwards, R. S. Houk, and J. L. Thompson,J. Nutr. 119, 1647 (1989).
J. Eagles, S. J. Fairweather-Tait, F. A. Mellon, D. E. Portwood, and R. Self,Rapid Comm. Mass Spect. 3(6), 203 (1989).
R. E. Serfass, J. J. Thompson, and R. S. Houk,Anal. Chim. Acta 188, 73 (1986).
P. K. Pierce, K. M. Hambidge, C. H. Goss, L. V. Miller, and P. V. Fennessey,Anal. Chem. 59, 2034 (1987).
H. P. Longerich, D. F. Strong, and C. J. Kantipuly,Can. J. Spectrosc. 31, 111 (1986).
B. T. G. Ting and M. Janghorbani,JAAS 3, 325 (1988).
J. K. Friel, C. S. Skinner, S. E. Jackson, and H. P. Longerich,Analyst,115, 269 (1990).
P. De Bievre and I. L. Barnes,Int. J. Mass Spectrom. Ion Processes 65, 211 (1985).
J. K. Friel, V. L. Naake, Jr., L. V. Miller, P. V. Fennessey, and K. M. Hambidge,Am. J. Clin. Nutr. 55, 365 (1992).
J. K. Friel and C. Nguyen,Clin. Chem. 32, 739 (1986).
H. Kingston, I. L. Barnes, and J. T. Brady,Anal. Chem. 50, 2064 (1978).
K. A. Krauss and G. E. Moore,J. Am. Chem. Soc. 75, 1457 (1953).
H. P. Longerich,ICP Information Newsletter, 1992,18, 32 (1992).
G. A. Jenner, H. P. Longerich, S. E. Jackson, and B. J. Fryer,Chem. Geol. 83, 133 (1990).
R. Barnes,Can. Spect. Soc., Ottawa, Ontario, Abstract in proceedings, August 11, 1991.
R. S. Gibson,Prog. Food. Nutr. Sc. 13, 67 (1989).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Friel, J.K., Longerich, H.P. & Jackson, S.E. Determination of isotope ratios in human tissues enriched with zinc stable isotope tracers using inductively coupled plasma-mass spectrometry (ICP-MS). Biol Trace Elem Res 37, 123–136 (1993). https://doi.org/10.1007/BF02783788
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02783788