Abstract
Equivalent two-port measurement equations for reciprocaln-port network are derived. As an example, applications of these equations, measurement details and data-processing methods are discussed for any three-port network. To realize rapid and automatic measurements ofS-parameters of any reciprocal multiport network, a set of measurement system which is composed of auto-slotted line and program controlled movable shorts is presented in this paper. Experimental data are given for an H-plane three-port network.
Similar content being viewed by others
References
R. W. Beatty, A. C. Macpherson,Proc. IRE,41 (1953), 1112–1118.
C. T. M. Chang,IEEE Trans. on MTT,MTT-20 (1973), 186–187.
S. Stein,Proc. IRE,42 (1954) 3, 599.
T. Nemoto, D. F. Wait,Trans. on MTT,MTT-16 (1968), 866–873.
J. D. Pieerese, W. Versnel,Appl. Sci. Res.,21 (1969) 8, 13–23.
D. Kajfez,IEEE Trans. on IM,IM-24 (1975) 1, 4–11.
Author information
Authors and Affiliations
About this article
Cite this article
Hongxiong, W. Equivalent two-port measurement equations for reciprocal multiport network and their applications. J. of Electron.(China) 9, 238–245 (1992). https://doi.org/10.1007/BF02778735
Issue Date:
DOI: https://doi.org/10.1007/BF02778735