Skip to main content

The use of Vicryl Collagen® as a dura substitute: A clinical review of 78 surgical cases

Summary

We performed a retrospective review of 78 consecutive neurosurgical procedures using Vicryl Collagen®, a resorbable mesh of polyglactin 910 coated with bovine collagen, for dural substitution. The complications we encountered were infrequent and mostly minor (5 cases of subcutaneous CSF collections, 2 cases of aseptic meningitis, 1 superficial wound infection), and not unusual for the surgical procedures studied. One patient, however, had a major infection, starting in the superficial tissues, and extending toward the brain. In this patient, the resorption of the dural substitute appeared to be the cause for the intracranial extension of the infection. Three patients were reoperated on for recurrent tumour after a longer interval. We found minimal adhesions and good fibrous incorporation of the Vicryl Collagen® into the surrounding normal dura. We conclude that Vicryl Collagen® is a valuable alternative to the patient’s own fibrous tissues when dural substitution is necessary.

This is a preview of subscription content, access via your institution.

References

  1. Carmel PW, Greif LK (1993) The aseptic meningitis syndrome: a complication of posterior fossa surgery. Pediatr Neurosurg 19: 276–280

    PubMed  CAS  Google Scholar 

  2. Collins RLL, Christiansen D, Zazanis GA, Silver FH (1991) Use of collagen film as a dural substitute: preliminary animal studies. J Biomed Mater Res 25: 267–276

    PubMed  Article  CAS  Google Scholar 

  3. Fontana R, Talamonti G, D’Angelo V, Arena O, Monte V, Collice M (1992) Spontaneous haematoma as unusual complication of silastic dural substitute. Report of 2 cases. Acta Neurochir (Wien) 115: 64–66

    Article  CAS  Google Scholar 

  4. Gorham SD, Monsour MJ, Scott R (1987) The in vitro assessment of a collagen/Vicryl (polyglactin) composite film together with candidate suture materials for use in urinary tract surgery. I Physical testing. Urol Res 15: 53–59

    PubMed  Article  CAS  Google Scholar 

  5. Gudmundsson G, Sogaard I (1995) Complications to the use of Vicryl-Collagen dural substitute. Acta Neurochir (Wien) 132: 145–147.

    Article  CAS  Google Scholar 

  6. Keller JT, Weil SM, Ongkiko CM, Tew JM, Mayfield FH, Dunsker SB (1989) Repair of spinal dural defects with Vicryl (polyglactin 910) mesh. J Spinal Disord 2: 87–92

    PubMed  Article  CAS  Google Scholar 

  7. Laquerrière A, Yun J, Tiollier J, Hémet J, Tadie M (1993) Experimental evaluation of bilayered human collagen as a dural substitute. J Neurosurg 78: 487–491.

    PubMed  Google Scholar 

  8. Maurer PK, McDonald JV (1985) Vicryl (polyglactin 910) mesh as a dural substitute. J Neurosurg 63: 448–452

    PubMed  CAS  Google Scholar 

  9. Meddings N, Scott R, Bullock R, French DA, Hide TA, Gorham SD (1992) Collagen Vicryl—a new dural prosthesis. Acta Neurochir (Wien) 117:53–58

    Article  CAS  Google Scholar 

  10. Meddings RN, Scott R, Buckley JF (1992) Dural prostheses, where do we go from here? Lancet 339: 127

    PubMed  Article  CAS  Google Scholar 

  11. Nussbaum CE, Maurer PK, McDonald JV (1989) Vicryl (polyglactin 910) mesh as a dural substitute in the presence of pia arachnoid injury. J Neurosurg 71: 124–127

    PubMed  CAS  Google Scholar 

  12. Narotam PK, Van Dellen JR, Bhoola KD (1995) A cliniopathological study of collagen sponge as a dural graft in neurosurgery. J Neurosurg 82: 406–412

    PubMed  CAS  Article  Google Scholar 

  13. Parizek J, Mericka P, Spacek J, Nemecek S, Elias P, Sercl M (1989) Xenogeneic pericardium as a dural substitute in reconstruction of suboccipital dura meter in children. J Neurosurg 70: 905–909

    PubMed  CAS  Google Scholar 

  14. San-Galli F, Darrouzet V, Rivel J, Baquey C, Ducassou D, Guérin J (1992) Experimental evaluation of a collagen-coated Vicryl mesh as a dural substitute. Neurosurgery 30: 396–401

    PubMed  CAS  Article  Google Scholar 

  15. Sharkey PC, Usher FC, Robertson RCL, Pollard C Jr (1958) Lyophilized human dura mater as a dural substitute., J Neurosurg 15: 192–198

    PubMed  CAS  Article  Google Scholar 

  16. Siccardi D, Ventimiglia A (1995) Fibrotic—haemorrhagic reaction to synthetic dural substitute. Acta Neurochir (Wien) 132: 148–149

    Article  CAS  Google Scholar 

  17. Thadani V, Penar PL, Partington J, Kalb R, Janssen R, Schonberger LB, Rabkin CS, Prichard JW (1988) Creutzfeldt-Jakob disease probably acquired from a cadaveric dura mater graft. Case report. J Neurosurg 69: 766–769

    PubMed  CAS  Google Scholar 

  18. Thammavaran KV, Benzel EC, Kesterson L (1990) Fascia lata graft as a dural substitute in neurosurgery. South Med J 83: 634–636

    Article  Google Scholar 

  19. Thompson D, Taylor W, Hayward R (1994) Haemorrhage associated with silastic dural substitute. J Neurol Neurosurg Psychiatry 57: 646–648

    PubMed  CAS  Google Scholar 

  20. Van Loon J, Plets C, Goffin J, Van Calenbergh F (1996) A prospective study of polyesterurethane (Neuro-patch) as durasubstitute. In: Abstractbook. Modern concepts of dural substitution. 10th European Congress of Neurosurgery, Berlin, May 7–12, 1995, Braun, Melsungen

    Google Scholar 

Download references

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Van Calenbergh, F., Quintens, E., Sciot, R. et al. The use of Vicryl Collagen® as a dura substitute: A clinical review of 78 surgical cases. Acta neurochir 139, 120–123 (1997). https://doi.org/10.1007/BF02747191

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02747191

Keywords

  • Vicryl Collagen®
  • dural substitute
  • dural defect