A magnetic differential probe. Its employment for the determination of the static median magnetic surface in the gap of a synchrotron

  • G. Diambrini Palazzi
Article

Summary

A differential magnetic probe, developed for determining the median magnetic surface of the static field in a weak-focusing synchrotron gap, is described. The probe consists of two thin ferromagnetic wires subjected to equal and opposite alternating magnetic fields at 1000 Hz. The method of measurement consists in determining the position of the probe for which the components of the magnetic field along the two wires (parallel to the radius of the synchrotron and lying in a vertical plane) are equal and opposite. The arrangement described gives the localisation of the median magnetic surface within ± 1 mm in static fields between 20 and 500 gauss. The possibility is also mentioned of measuring the field indexn by means of this probe with an accuracy of 5 % in fields not exceeding 500 gauss. Finally the technique used for preparing the ferromagnetic wires is explained in some detail.

Riassunto

Viene descritta una sonda differenziale magnetica realizzata con lo scopo di determinare la superficie magnetica mediana del campo statico nell’intraferro di un sincrotrone a focalizzazione debole. La sonda è costituita da due sottili fili ferromagnetici sottoposti a campi magnetici alternati a 1000 Hz uguali e opposti in ogni istante. II metodo di misura consiste nel determinare la posizione della sonda per cui le componenti del campo magnetico lungo i due fili (paralleli al raggio del sincrotrone e giacenti in un piano verticale), sono uguali e opposte. Il dispositivo descritto permette la localizzazione della superficie magnetica mediana entro ± 1 mm in campi statici tra 20 e 500 gauss. Si accenna pure alla possibilità di misurare l’indice di campon mediante questa stessa sonda con la precisione del 5 % in campi non maggiori di 500 gauss. Infine viene esposta con qualche dettaglio la tecnica usata per la preparazione del fili ferromagnetici.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. (1).
    J. M. Kelly:Rev. Sci. Instr.,22, 256 (1951);S. Giordano, G. K. Green andE. J. Rogers:Rev. Sci. Instr.,24, 848 (1953).ADSCrossRefGoogle Scholar
  2. (2).
    G. Salvini:Suppl. Nuovo Cimento,2, 442 (1955).ADSCrossRefGoogle Scholar
  3. (3).
    E. Weber:Electromagnetic Fields (New York) p. 242.Google Scholar
  4. (4).
    P. M. S. Blackett:Phil. Trans. Roy. Soc. London, A245, 309 (1952).ADSCrossRefGoogle Scholar
  5. (5).
    R. O. Wjchoff:Geophysics,13, 182 (1948).ADSCrossRefGoogle Scholar
  6. (6).
    Journ. Appl. Phys.,26, 8 (1955).Google Scholar

Copyright information

© Società Italiana di Fisica 1956

Authors and Affiliations

  • G. Diambrini Palazzi
    • 1
  1. 1.Sezione AcceleratoreIstituto Nazionale di Fisica NucleateRoma