Skip to main content
Log in

Analytical methods for RE-Co alloys

  • Published:
Bulletin of Materials Science Aims and scope Submit manuscript

Abstract

Total RE, Co and Fe in mischmetal and its cobalt alloys are determined by visual complexometric methods and instrumental x-ray fluorescence techniques. As Fe causes interference in the determinations of RE and Co and its own determination is affected by the presence of Co, it is removed by precipitation. The iron is determined from the precipitate and RE and Co from the filtrate. Accuracy of the method is checked by analysing synthetic mixtures of RE, Co and Fe. The individual REs in mischmetal are determined by x-ray fluorescence method. The analysis technique is based on comparison of the oxides of the test samples with standards (both in pressed pellet form) in the appropriate composition range. The total RE content of mischmetal determined through complexometric analysis is compared with the total RE determined through x-ray fluorescence.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alota S and Bartoli P 1975Metall. Ital. 67 655; (1976)Chem. Abstr. 85 56142 V

  • Ayres G H 1958Quantitative chemical analysis (New York: Harper and Brothers) p. 251

    Google Scholar 

  • Bertin E P 1970Principles and practice of x-ray fluorescence spectrometry analysis (New York: Plenum Press)

    Google Scholar 

  • Bonnevie-Svendsen M and Follo A 1973Anal. Appl. Rare Earth Mater., NATO Adv. Study Inst. 1972, p. 87; (1975)Chem. Abstr. 82 148943 Y.

  • Brusdeylins A 1975 Goldschmidt Informiert 4/75Nr. 35, 34

    Google Scholar 

  • Chandola L C, Machado I J and Mohile A N 1975A.E.C. BARC (Rep.) p. 819; (1976)Chem. Abstr. 85 86738 m

  • Gupta K P and Bhat S P 1974X-ray data book, (Kanpur: Indian Institute of Technology),

    Google Scholar 

  • Higashi K and Miyake Y 1975Osaka Kogyo Gijutsu Shikensho Kiho 26 1315; (1976)Chem. Abstr. 85 103313 p

    Google Scholar 

  • Lytle F W, Botsford J I and Heller H A 1957Adv. X-ray Anal. 1 367

    Google Scholar 

  • Pribil R 1967Talanta 14 1619

    Google Scholar 

  • Sasaki N 1973Bunseki Kiki 11 371; (1974)Chem. Abstr. 80 R 43630 2

    CAS  Google Scholar 

  • Tertian R 1968Adv. X-ray Anal. 12 546

    Google Scholar 

  • Zimkova L V, Lrumpova M J, Stuasco V S and Kirsanov L J 1973Zavod. Lab. 39 631; (1973)Chem. Abstr. 73 61153 e

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Padmavathy Sankar, T.A., Gupta, H.O., Subbarao, E.C. et al. Analytical methods for RE-Co alloys. Bull. Mater. Sci. 2, 167–176 (1980). https://doi.org/10.1007/BF02745404

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02745404

Keywords

Navigation