Summary
The light response of a NE102A-BaF2 phoswich detector to low-energy heavy ions (Z⩽10) has been studied. It is shown that in a fast-total component representation heavy ions punching through the plastic can be separated in charge, provided that time-of-flight measurements are also available, in order to separate γ-rays and light charged particles from overlapping low-Z heavy ions. Despite the good timing properties of the detector (Δt<250 ps), their mass separation is limited by the scarce energy resolution of the system, especially for very low-energy heavy ions. An evaluation of energy resolution and quenching effects is also given.
Similar content being viewed by others
References
G. Lanzanò, A. Pagano, S. Urso, E. De Filippo, B. Berthier, J. L. Charvet, R. Dayras, R. Legrain, R. Lucas, C. Mazur, E. Pollacco, J. E. Sauvestre, C. Volant, C. Beck, B. Djerroud andB. Heusch:Nucl. Instrum. Methods A,312, 515 (1992).
E. De Filippo: Doctoral Thesis, Università di Catania (1992), unpublished;J. E. Sauvestre: Doctoral Thesis, Univerité de Caen (1992), unpublished.
A. Del Zoppo, C. Agodi, R. Alba, G. Bellia, R. Coniglione, C. Maiolino, E. Migneco, A. Peghaire, P. Piattelli andP. Sapienza:Nucl. Instrum. Methods A,327, 363 (1993).
D. H. Wilkinson:Rev. Sci. Instrum.,23, 414 (1952);D. Bodansky andS. F. Eccles:Rev. Sci. Instrum.,28, 464 (1957).
J. Alarja, A. Dauchy, A. Giorni, C. Morand, E. Pollacco, P. Stassi, R. Billerey, B. Chambon, B. Cheynis, D. Drain andC. Pastor:Nucl. Instrum. Methods A,242, 352 (1986).
G. Lanzanò, A. Pagano, E. De Filippo, E. Pollacco, R. Barth, B. Berthier, E. Berthoumieux, Y. Cassagnou, Sl. Cavallaro, J. L. Charvet, A. Cunsolo, R. Dayras, A. Foti, S. Harar, R. Legrain, V. Lips, C. Mazur, E. Norbeck, S. Urso andC. Volant:Nucl. Instrum. Methods A,323, 694 (1992).
Y. Futami, T. Mizota, Y. H. Pu, Y. Honio, K. Yuasa-Nakagawa, H. Toyokava, S. m. Lee, K. Furutaka, T. Murakami, J. Kasagi, K. Yoshida andT. Nakagawa:Nucl. Instrum. Methods A,326, 513 (1993).
E. Migneco, C. Agodi, R. Alba, G. Bellia, R. Coniglione, A. Del Zoppo, P. Finocchiaro, C. Maiolino, P. Piattelli, G. Raia andP. Sapienza:Nucl. Instrum. Methods A,314, 31 (1992).
See, for instance,Proceedings of the Symposium on Nuclear Dynamics and Nuclear Disassembly, edited byJ. B. Natowitz (World Scientific, Singapore, 1989).
E. Dafni:Nucl. Instrum. Methods A,254, 54 (1987).
E. De Filippo, G. Lanzanò, A. Pagano, S. Urso, B. Bertier, J. L. Charvet, R. Dayras, R. Legrain, R. Lucas, C. Mazur, E. Pollacco, J. E. Sauvestre, C. Volant, C. Beck andS. Djerroud:Nucl. Instrum. Methods A,342, 527 (1994).
S. Kubota, M. Suzuki, J. Ruan(Gen), F. Shiraishi andY. Takami:Nucl. Instrum. Methods A,242, 291 (1986).
J. L. Charvet: Code Eloise, unpublished.
T. Murakami, J. Kasagi, H. Tachibanachi, K. Yoshida, Y. Shibata, T. Nakagava, M. Ogihara, S. M. Lee, T. Kubo andT. Motobayashi:Nucl. Instrum. Methods A,253, 163 (1986).
Author information
Authors and Affiliations
Additional information
Experiment performed at LNS, Catania.
Mr. V. Campagna and Mr. S. Urso for help during the mounting of the experiment.
Rights and permissions
About this article
Cite this article
De Filippo, E., Fonte, R., Lanzanò, G. et al. The response of a NE102A-BaF2 phoswich detector to low-energy heavy ions. Nuov Cim A 107, 775–782 (1994). https://doi.org/10.1007/BF02732085
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF02732085