Skip to main content
Log in

Electronic equipment for measuring ionization in nuclear plates

  • Note Tecniche
  • Published:
Il Nuovo Cimento (1955-1965)

Summary

The drum revolution of a motor-driven mycroscope micrometric eyepiece is read by means of a phototube arrangement originating calibrated electric pulses. The pulses are counted and compared by an equipment incorporating one decade counter tube channel and several condenser storage counters. Final information including track length, mean gap length and gap distribution is directly displayed by electromechanical counters. An analysis of condenser storage counters is given in the Appendix.

Riassunto

La determinazione dei vari parametri di ionizzazione in emulsioni nucleari, viene realizzata per mezzo di un apparecchio semiautomatico associato al micrometro oculare a filo microscopio. Nella misura si fa ruotare il tamburo del micrometro mediante un motore comandato a pedale dall’operatore. La rotazione del tamburo è letta da un dispositivo foto-elettrico che genera impulsi calibrati. Questi impulsi vengono contati e confrontati da un contatore decadico e da vari contatori ad accumulazione. Le grandezze misurate sono registrate da numeratori telefonici e comprendono: lunghezza totale di traccia misurata, numero dei « gap » e numero dei α gap » di lunghezza maggiore di certi valori prefissati. In appendice è riportata l’analisi dei circuiti integratori ad accumulazione.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. H. Fowler andD. H. Perkins:Phil. Mag.,46, 587 (1955).

    Article  Google Scholar 

  2. D. M. Ritson:Phys. Rev.,91, 1572 (1953).

    Article  ADS  Google Scholar 

  3. G. Baroni andC. Castagnoli:Suppl. Nuovo Cimento,12, 364 (1954).

    Article  Google Scholar 

  4. M. Della Corte:Nuovo Cimento,12, 28 (1954).

    Article  Google Scholar 

  5. J. E. Hooper, andM. Scharff:CERN Secr. St. Meas., no. 12 (1954).

  6. M. Renardier andY. Avignon:Compt. Rend.,233, 393 (1951).

    Google Scholar 

  7. H. M. Mayer:CERN Secr. St. Meas., no. 20 (1955).

  8. M. V. Klein:Rev. Sci. Instr.,28, 964 (1957).

    Article  ADS  Google Scholar 

  9. K. Enslein: Private communication.

  10. G. Cortini, A. Manfredini, A. De Marco, R. Sanna andG. Tomasini:Report on Padua-Venice Conference, September 1957.

  11. C. O’Ceallaigh:CERN Secr. St. Meas., no. 11 (1954); see also,R. H. W. Johnston andC. O’Ceallaigh:Phil. Mag.,45, 424 (1954);Nuovo Cimento,1, 468 (1955).

  12. Millman-Taub:Pulse and Digital Circuits (New York, 1956), pp. 346–353.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

De Marco, A., Sanna, R. & Tomasini, G. Electronic equipment for measuring ionization in nuclear plates. Nuovo Cim 9, 524–532 (1958). https://doi.org/10.1007/BF02725107

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02725107

Navigation