Skip to main content
Log in

Non invasive continuous anterior fontanel tension monitoring in neonates

  • Original Articles
  • Published:
The Indian Journal of Pediatrics Aims and scope Submit manuscript

Abstract

Anterior fontanel tension (AFT) has been shown to reflect the intracranical pressure (ICP). A new transducer was designed for AFT measurement which overcomes the problems of replacement in subsequent use. Using the transducer AFT was monitored noninvasively over extended periods in about 200 normal and sick neonates. The results indicate that the technique can be used to identify elevated pressure due to different disease conditions and it has a potential to help in understanding physiological and pathological mechanisms causing alterations in the normal cerebrospinal dynamics. Further studies are underway to establish the full potentials of the technique.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Davidoff LM, Chamlin M. The fontanometric adaptation of Schiotz tonometer for determination of ICP in neonatal and early periods of infancy.Pediatrics 1959; 24: 1065–1068.

    PubMed  CAS  Google Scholar 

  2. Vidyasagar D, Raju TNK. A simple non-invasive technique of measuring intracranial pressure in newborn.Pediatrics 1977; 59: 957–961.

    PubMed  Google Scholar 

  3. Kosmetatos N, William ML. Effect of positioning and head bending on intracranial pressure in premature infants.Pediatr Res 1978: 12:553.

    Article  Google Scholar 

  4. Horbar, JD, Yeager S, Philip AGS et al. Effect of application force on non-invasive measurement of intracranial pressure.Pediatrics 1980; 66: 455–458.

    PubMed  CAS  Google Scholar 

  5. Hill A. Intracranial pressure measurements in the newborns.Clin Perinatol 1985; 12 (i): 161–178.

    PubMed  CAS  Google Scholar 

  6. Vidyasagar D, Raju TNK, Chiang J. Clinical significance of monitoring anterior fontanel pressure in sick neonates and infants.Pediat rics 1978; 62: 996–999.

    CAS  Google Scholar 

  7. Volpe JJ.Neurology of Newborn. Philadelphia: WB Saunders & Co. 1981.

    Google Scholar 

  8. Phillip AGS. Non-invasive monitoring of intracranial pressure.Clin Perinatol 1979; 6(i) 123–136.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sharma, J., Bhargava, S.K., Anand, S. et al. Non invasive continuous anterior fontanel tension monitoring in neonates. Indian J Pediatr 56, 765–769 (1989). https://doi.org/10.1007/BF02724462

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02724462

Keywords

Navigation