Skip to main content
Log in

Enhancement of UV disinfection efficiency by arraying inclined lamps

  • Published:
Korean Journal of Chemical Engineering Aims and scope Submit manuscript

Abstract

A computational study on UV disinfection efficiency has been developed based on the Lambert-Beer law. Comparing a UV lamp arranged vertically to the flow of one arranged on an incline led to the conclusion that UV doses could be increased. The study of the inclination effect was divided into four stages in order to evaluate the increase in the UV dose at each stage. The slope of the inclined UV lamp ranged between 1‡ and 89‡ (0‡<θ<90‡) with other parameters such as diameter of the UV lamp, distance from the surface of the UV lamp, and velocity also recorded. The increase of UV dosage was largely affected by the diameter and velocity of the UV lamp, especially on a lesser slope. To obtain a greater UV dose, it was necessary to assemble UV lamps with lesser slopes. By arranging lamps on an incline, UV disinfection could be enhanced.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alam, M. Z. B., Otaki, M., Furumai, H. and Ohgaki, S., “Direct and indirect inactivation of Microcystis Aeruginosa by UV-radiation,”Water Res.,35(4), 1008 (2001).

    Article  CAS  Google Scholar 

  • Andreadakis, A., Mamais, D., Christoulas, D. and Kabylafka, S., “Ultraviolet disinfection of secondary and tertiary effluent in the mediterranean region,”Water Sci. Technol.,40(4–5), 253 (1999).

    Article  CAS  Google Scholar 

  • Blatchley, E. R. III, Wood, W. L. and Schuerch, P., “UV pilot testing: intensity distribution and hydrodynamics,”J. Environ. Eng.,121(3), 258 (1995).

    Article  CAS  Google Scholar 

  • Campbell, A. T. and Wallis, P., “The effect of UV irradiation on humanderived Giardia Lambia cysts,”Water Res.,36(4), 963 (2002).

    Article  CAS  Google Scholar 

  • Craik, S. A., Weldon, D., Finch, G. R., Bolton, J.R. and Belosevic, M., “Inactivation of Cryptosporidium Parvum Oocysts using mediumand low-pressure ultraviolet radiation,”Water Res.,35(6), 1387 (2001).

    Article  CAS  Google Scholar 

  • Iranpour, R., Garnas, G., Moghaddam, O. and Taebi, A., “Hydraulic effects on ultraviolet disinfection: modification of reactor design,”Water Environ. Res.,71(1), 114 (1999).

    Article  CAS  Google Scholar 

  • Jolis, D. and Hirano, R.,Microfiltration and ultraviolet light disinfection for water reclamation, Bur Eng Dep Public Works., City and County of San Francisco (1993).

    Google Scholar 

  • Loge, F. J., Emerick, R.W., Thompson, D. E., Nelson, D.C. and Darby, J. L., “Factors influencing ultraviolet disinfection performance part I: Light penetration to wastewater particles,”Water Environ. Res.,71(3), 377 (1999).

    Article  CAS  Google Scholar 

  • Moreno, B., Goni, F., Fernandez, O. and Martinez, J. A., “The disinfection of wastewater by ultraviolet light,”Water Sci. Technol.,35(11–12), 233 (1997).

    Article  CAS  Google Scholar 

  • Qualls, R.G., Flynn, M. P. and Johnson, J. D., “The role of suspended particles in ultraviolet disinfection,”J. Water Pol. Control Fed.,55, 1280 (1983).

    CAS  Google Scholar 

  • Rajala-Mustonen, R. L., Toivola, P. S. and Heinonen-Tanski, H., “Effects of peracetic acid and UV irradiation on the inactivation of coliphages in wastewater,”Water Sci. Technol.,35(11–12), 237 (1997).

    Article  CAS  Google Scholar 

  • Scheible, O.K., “Development of a rationally based design protocol for the UV light disinfection process,”J. Water Pol. Control Fed.,59, 25 (1987).

    CAS  Google Scholar 

  • USEPA,Ultraviolet disinfection technology assessment, EPA 832 R-92-004 (1992).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoon-Jin Lee.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lim, SJ., Lee, YJ. Enhancement of UV disinfection efficiency by arraying inclined lamps. Korean J. Chem. Eng. 23, 595–600 (2006). https://doi.org/10.1007/BF02706800

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02706800

Key words