Skip to main content
Log in

A possibility of parallel and anti-parallel diffraction measurements on neutron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition

  • Published:
Pramana Aims and scope Submit manuscript

Abstract

In a conventional diffractometer having single monochromator, only one position, parallel position, is used for the diffraction experiment (i.e. detection) because the resolution property of the other one, anti-parallel position, is very poor. However, a bent perfect crystal (BPC) monochromator at monochromatic focusing condition can provide a quite flat and equal resolution property at both parallel and anti-parallel positions and thus one can have a chance to use both sides for the diffraction experiment. From the data of the FWHM and the Δd/d measured on three diffraction geometries (symmetric, asymmetric compression and asymmetric expansion), we can conclude that the simultaneous diffraction measurement in both parallel and anti-parallel positions can be achieved.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G E Bacon,Neutron diffraction (Clarendon Press, Oxford, 1975) pp. 101–111

    Google Scholar 

  2. F Rustichelli,Nucl. Instrum. Methods 74, 219 (1969)

    Article  ADS  Google Scholar 

  3. T Riste,Nucl. Instrum. Methods 86, 1 (1970)

    Article  Google Scholar 

  4. J Klaus,J. Appl. Crystallogr. 8, 361 (1975)

    Article  Google Scholar 

  5. J Kulda and P Mikula,J. Appl. Crystallogr. 16, 498 (1983)

    Article  Google Scholar 

  6. J Saroun,J. Appl. Crystallogr. 27, 80 (1994)

    Article  Google Scholar 

  7. P Mikula, V Wagner and R Scherm, PTB-N-17, Braunschweig (1994)

  8. V Wagner, P Mikula and P Lukas,Nucl. Inst. & Meth. in Phys. Res. A338, 53 (1994)

    Article  ADS  Google Scholar 

  9. P Mikula, P Lukas and R Michalec,J. Appl. Crystallogr. 20, 428 (1987)

    Article  Google Scholar 

  10. P Mikula, J Kulda, P Lukas, M Vrana and V Wagner,Nucl. Inst. & Meth. in Phys. Res. A338, 18 (1994)

    Article  ADS  Google Scholar 

  11. P Mikula, M Vrana, Y N Choi, S A Kim, H S Oh, K H Sung, C H Lee, M R Muslih and N Nimura,Proceedings of the 7th World Conference on Neutron Radiography, Roma, Italy (2002)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Choi, Y.N., Kim, S.A., Kim, S.K. et al. A possibility of parallel and anti-parallel diffraction measurements on neutron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition. Pramana - J Phys 63, 175–181 (2004). https://doi.org/10.1007/BF02704064

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02704064

Keywords

PACS No.

Navigation