Abstract
A simple method of identifying the initial slope of the stress-strain curve (i.e., Young's modulus of the soft tissue) by introducing the pipette aspiration technique is presented. The tissue was assumed to be isotropic and macroscopically homogeneous. Numerical simulations by the linear finite element analysis were performed for the axisymmetric model to survey the effects of friction at the tissue-pipette contact boundary, pipette cross-sectional geometry, relative size of the specimen to the pipette, and the layered inhomogeneity of the specimen tissue. The friction at the contact region had little effect on the measurement of Young's modulus. The configuration of the pipette was shown to affect the measurement for small pipette wall thickness. The measurement also depended on the relative size of the specimen to the pipette for relatively small specimens. The extent of the region contributing to the measurement was roughly twice the inside radius of the pipette. In this region, the maximum stress did not exceed the level of the aspiration pressure, with only minor exceptional locations. Calculation of strain energy components indicated that the major contributions to the deformation under pipette aspiration were by the normal extension and shear deformation in pipette axial direction. Experimental verification of the present method for the isotropic, homogeneous artificial material is also presented.
Similar content being viewed by others
References
Cook, T., H. Alexander, M. L. Cohen. Experimental method for determining the 2-dimensional mechanical properties of living human skin.Med. Biol. Eng. Comput. 15:381–390, 1977.
Evans, E. A. New membrane concept applied to the analysis of fluid shear- and micropipette-deformed red blood cells.Biophys. J. 13:941–954, 1973.
Fung, Y. C. Biomechanics: Mechanical Properties of Living Tissues. New York: Springer-Verlag, 1981, 433 pp.
Glagov, S., C. K. Zarins, D. P. Giddens and H. R. Davis. Atherosclerosis: what is the nature of the plaque? In: Vascular diseases: current research and clinical applications edited by D. E. Strandness, P. Didisheim, J. T. Watson, and A. W. Clowes. Orlando: Grune & Stratton, 1987, pp. 15–33.
Gow, B. S., and R. M. Vaishnav. A microindentation technique to measure rheological properties of the vascular intima.J. Appl. Physiol. 38:344–350, 1975.
Gow, B. S., W. D. Castle, and M. J. Legg. An improved microindentation technique to measure changes in properties of arterial intima during atherogenesis.J. Biomech. 16:451–458, 1983.
Kataoka, N., T. Ohashi, T. Matsumoto, T. Aoki, and M. Sato. Application of the pipette aspiration technique to the measurement of local elastic moduli of cholesterol-fed rabbit aortas. In: Theoretical and applied mechanics, vol. 43, edited by M. Hori and T. Nakamura. Tokyo: The Japan National Committee for Theoretical and Applied Mechanics, 1994, pp. 233–238.
Loree, H. M., A. J. Grodzinsky, S. Y. Park, L. J. Gibson, and R. T. Lee. Static circumferential tangential modulus of human atherosclerotic tissue.J. Biomech. 27:195–204, 1994.
Richardson, P. D., M. J. Davies, and G. V. R. Born. Influence of plaque configuration and stress distribution on fissuring of coronary atherosclerotic plaques.Lancet 2:941–944, 1989.
Sato, M., M. J. Levesque, and R. M. Nerem. An application of the micropipette technique to the measurement of the mechanical properties of cultured bovine aortic endothelial cells.ASME J. Biomech. Eng. 109:27–34, 1987.
Theret, D. P., M. J. Levesque, M. Sato, R. M. Nerem, and L. T. Wheeler. The application of a homogeneous half-space model in the analysis of endothelial cell micropipette measurements.ASME J. Biomech. Eng. 110:190–199, 1988.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Aoki, T., Ohashi, T., Matsumoto, T. et al. The pipette aspiration applied to the local stiffness measurement of soft tissues. Ann Biomed Eng 25, 581–587 (1997). https://doi.org/10.1007/BF02684197
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02684197