Abstract
Malpositioned central venous catheters must be repositioned in order to avoid damage caused by concentrated or irritating infusates. Floppy catheters may be repositioned rapidly with a brisk injection of fluid. The ease of this technique, with its anticipated low risk of infection, makes it an attractive alternative to manipulation using guidewires.
Similar content being viewed by others
References
Bottino J, McCredie KB, Groschell DHM, Lawson M (1979) Long-term intravenous therapy with peripherally inserted silicone elastomer central venous catheters in patients with malignant diseases Cancer 43:1937–1943
Costanzo JD, Sastre B, Choux R, Kasparian M (1988) Mechanism of thrombogenesis during total parenteral nutrition: Role of catheter composition. JPEN 12:190–194
Hoshal VL (1975) Total intravenous nutrition with peripherally inserted silicone elastomer central venous catheters. Arch Surg 110:644–646
MacDonald SA, Master SKP, Moffitt FA (1977) A comparative study of peripherally inserted silicone catheters for parenteral nutrition. Can Anaesth Soc J 24:263–269.
Slater H, Goldfarb IW, Jacob HE, Hill JB, Srodes CH (1985) Experience with long-term outpatient venous access utilizing percutaneously placed silicone elastomer catheters Cancer 56:2074–2077
Sketch MH, Cale M, Mohiuddin SM, Booth RW (1972) Use of percutaneously inserted venous catheters in coronary care units Chest 62:684–689
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Olcott, E.W., Gordon, R.L. & Ring, E.J. The injection technique for repositioning central venous catheters: Technical note. Cardiovasc Intervent Radiol 12, 292–293 (1989). https://doi.org/10.1007/BF02575420
Issue Date:
DOI: https://doi.org/10.1007/BF02575420