Abstract

Quantitative intraarterial digital subtraction arteriography (DSA) was performed using a calibration catheter with three distal metallic ring markers. The two outer markers were 50 mm apart, and the third marker was in the middle. Measurements of 54 vessel diameters of the abdominal aorta, renal, lumbar, and iliac arteries were performed in a comparison study with direct film arteriograms in 10 aortofemoral runoff studies. Diameter measurements were made by both the observer on hard copy DSA images and by a computer using modified semiquantitative software. Against measurements on film, which were used as the standard, deviations in measurement on digital images varied from 8 to 13% for arterial diameters <5 mm and from 2 to 6% for diameters ≥5 mm. Projectional artifacts caused 3% or less error. Knowing these variations in measurement is important in order to determine error tolerances for clinical applications. The calibration catheter serves as a convenient internal marker for DSA.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Lee KR, Cox GG, Price HI, Batnitzky S, Dwyer SJ (1983) A metric ruler for digital subtraction angiography. Radiology 148:296

    PubMed  CAS  Google Scholar 

  2. Braun SD, Illescas FF, Fagert T, Dunnick RN (1985) Measuring abdominal aortic aneurysms on digital subtraction arteriograms. AJR 144:997–998

    PubMed  CAS  Google Scholar 

  3. Halden WJ, White RI, Bright J, Mitchell SE, Chang R (1986) Vessel sizing wire: Accurate vessel measurement using digital subtraction arteriography. Radiology 161:556–557

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Barth, K.H., Kremers, P.W., Lindisch, D. et al. Quantitative digital subtraction arteriography with a calibration catheter. Cardiovasc Intervent Radiol 12, 281–285 (1989). https://doi.org/10.1007/BF02575417

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02575417

Key words

Navigation