Abstract
An intact anti CEA monoclonal antibody (C198) and its F(ab)2 and Fab fragments have been radiolabelled with131I and111In and their biodistributions and tumour imaging capabilities examined in mice with human tumour xenografts.131I labelled F(ab)2 and Fab fragments showed improved tumour visualization compared with intact antibody, principally because of the more rapid whole body elimination of the radiolabel. Studies using111In labelled fragments demonstrated that a major proportion (>60%) of the administered radioactivity was retained in the kidneys and this was detrimental to tumour imaging in the mouse xenograft model. The present study emphasizes the importance of selecting the most appropriate combination of antibody preparation and radiolabel, and that the choice of radionuclide is influenced by both its physical and subsequent pharmacological characteristics.
Similar content being viewed by others
References
Andrew SM, Pimm MV, Perkins AC, Baldwin RW (1986) Comparative imaging and biodistribution studies with an anti-CEA monoclonal antibody and its F(ab)2 and Fab fragments in mice with colon carcinoma xenografts. Eur J Nucl Med 12:168–175
Arend WP, Silverblatt FJ (1975) Serum disappearance and catabolism of homologous immunoglobulin fragments in rats. Clin Exp Immunol 22:502–513
Buchegger F, Haskell CM, Scheryer M, Scazziga BR, Randin S, Carrel S, Mach JP (1983) Radiolabeled fragments of monoclonal antibodies against carcinoembryonic antigen for localization of human colon carcinoma grafted into nude mice. J Exp Med 158:413–427
Buraggi GL, Gallegaro L, Turrin A, Cascinelli N, Attili A, Emanuelli H, Gasparini M, Deleide G, Plassio G, Dovis M, Mariani G, Natali PG, Scassellati GA, Rosa U, Ferrone S (1984) Immunoscintigraphy with123I,99mTc and111 In-labelled F(ab′)2 fragments of monoclonal antibodies to a human high molecular weight-melanoma associated antigen. J Nucl Med Allied Sci 28:283–295
Childs RL, Hnatowich DJ (1985) Optimum conditions for labelling of DTPA-coupled antibodies with technetium-99m. J Nucl Med 26:292–299
Delaloye B, Bischof-Delaloy A, Buchegger F, Von Fliedner V, Grob J-P, Volani J-C, Pettavel J, Mach J-P (1986) Detection of colorectal carcinoma by emission-computerized tomography after injection of123I-labeled Fab or F(ab′)2 fragments from monoclonal anti carcinoembryonic antigen antibodies. J Clin Invest 77:301–311
Epenetos AA, Britton KE, Mather S, Granowska M, Taylor-Papadimitriou J, Nimmon CC, Durbin H, Hawkins LE, Malpas JS, Bodmer WF (1982) Targetting of iodine-123-labelled tumour-associated monoclonal antibodies to ovarian, breast and gastrointestinal tumours. Lancet 11:999–1004
Fairweather DS, Bradwell AR, Dykes PW, Vaughan AT, Watson-James SF, Chandler S (1983) Improved tumour localization using indium-111 labelled antibodies. Br Med J 287:167–170
Halpern SE, Hagan PL, Garver PR, Kozoil JA, Chen AWN, Frincke JM, Bartholomew RM, David GS, Adams TM (1983) Stability, characterization and kinetics of labeled111In monoclonal antitumor antibodies in normal animals and nude mouse-human tumor models. Cancer Res 43:5347–5355
Hnatowich DJ, Layne WW, Childs RL, Lanteigne D, Davis MA, Griffen TW, Doherty PW (1983) Radioactive labeling of antibody: a simple and efficient method. Science 220:613–615
Hnatowich DJ, Griffin TW, Kosciuczyk C, Rusckowski M, Childs RL, Mattis JA, Shealy D, Doherty PW (1985) Pharmacokinetics of an indium-111-labeled monoclonal antibody in cancer patients. J Nucl Med 26:849–858
Khaw BA, Cooney H, Edgington T, Strauss HW (1986) Differences in experimental tumor localization of dual-labeled monoclonal antibody. J Nucl Med 27:1293–1299
Perkins AC, Pimm MV (1985) Differences in tumour and normal tissue concentrations of iodine and indium-labelled monoclonal antibody. I. The effect on image contrast in clinical studies. Eur J Nucl Med 11:295–299
Perkins AC, Pimm MV, Andrew SM, Godden A, Frier M (1987) Tumour imaging characteristics of I-131, I-123, In-111 and Tc99m-labelled antibodies and Fab fragments. Nucl Med (in press)
Pimm MV, Perkins AC, Baldwin RW (1986) Labelling of monoclonal antibody with metallic radionuclides: preparation of antibody-DTPA conjugates from DTPA anhydride in organic solvent. IRCS Med Sci 14:104–105
Powe J, Pak KY, Paik CH, Steplewski Z, Ebbert MA, Herlyn D, Ernest C, Alavi A, Eckelman WC, Reba RC, Koprowski H (1984) Labeling monoclonal antibodies and F(ab′)2 fragments with (111 In) indium using cyclic DTPA anhydride and their in vivo behaviour in mice bearing human tumor xenografts. Cancer Drug Delivery 1:125–135
Rhodes BA, Zamora PO, Newell KD, Valdez EF (1986) Technetium-99m labeling of murine monoclonal antibody fragments. J Nucl Med 27:685–693
Wochner RD, Strober W, Waldmann TA (1967) The role of the kidney in the catabolism of Bence Jones proteins and immunoglobulin fragments. J Exp Med 126:207–221
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Andrew, S.M., Perkins, A.C., Pimm, M.V. et al. A comparison of iodine and indium labelled anti CEA intact antibody, F(ab)2 and Fab fragments by imaging tumour xenografts. Eur J Nucl Med 13, 598–604 (1988). https://doi.org/10.1007/BF02574776