Abstract
In recent years, various contrast media have been developed for use in coronary angiography. These contrast media may be divided into ionic contrast media of high osmolality, those of low osmolality, and nonionic contrast materials. We conducted our own clinical studies with 40 patients. In random succession a standard contrast medium (ionic, of high osmolality) and a new-generation contrast medium (either nonionic or ionic with low osmolality) were injected into the right and left coronary arteries. After each injection we measured the systolic and diastolic blood pressure using a liquid-filled coronary catherter. In addition, the change in the length of the cardiac cycle was registered in terms of the R-R interval (in ms) and at the same time, leads I, II, and III of the ECG were recorded. We studied the influence of the various contrast media on the activity of ATPase in in vitro experiments, using Lasser and Lang's [30]. When ionic contrast media of low osmolality and nonionic contrast media were utilized the heart rate showed no change. Disturbances of rhythm such as ventricular tachycardia or fibrillation were not observed. All of the contrast media used produced the same ECG changes. These changes can be ascribed to the inhibition of ATPase. The arterial blood pressure was lowered significantly only by ionic contrast media of high osmolality only.
Similar content being viewed by others
References
Adams DF, Fraser DB, Abrams HL (1973) The complications of coronary arteriography. Circulation 48:609–618
Aldo VE, Heeger H (1973) EKG-Veränderungen bei selektiver Koronarangiographie und Myokardszintingraphie. Z Kardiol 62:1078–1084
Bailey LE, Dresel PE (1968) Correlation of contractile force with a calcium pool in the isolated cat heart. J Gen Physiol 52:969–981
Banks DC, Raftery EB, Oram S (1969)_Evaluation of contrast media used in coronary arteriography. Br Heart J 31:645–648
Benchimol A, McNally EM (1976) Hemodynamic and electrocardiographic effects of selective coronary arteriography in man. N Engl J Med 274:1217–1223
Bourassa MG, Noble J (1976) Complication rate of coronary arteriography. A review of 5250 cases studied by a percutaneous femoral technique. Circulation 53:106–114
Björk L, Camrerini F, Larine GP (1969) Electrocardiographic changes during left heart and aortic angiocardiography with Urografin 76% and Isopaque 60%. Angiology 18:96–105
Brown TG Jr (1967) Cardiovascular actions of angiographic media. Angiology 18:273–281
Brown TG Jr, Hoppe JO, Borisenok WA (1967) Cardiovascular studies of Isopaque B and other radiopaque media. Acta Radiol (Suppl) 270:58–74
Carson RP, Weber WJ, Wilson WS (1969) Effect of selective coronary arteriography on myocardial blood flow in the intact dog. Am J Med Sci 257:228–233
Carson RP, Lazzara R (1970) Hemodynamic responses initiated by coronary stretch receptors with special reference to coronary arteriography. Am J Cardiol 25:571–578
Carter AM, Olin T (1975) Toxicity of roentgen contrast media at selective injection into the coronary artery in the rabbit. Invest Radiol 10:73–78
Chahine RA, Herman MV, Gorlin R (1972) Complications of coronary arteriography: Comparison of the branchial to the femoral approach (abstr). Ann Intern Med 76:862
Coskey RL, Magidson O (1967) Electrocardiographic response to selective coronary arteriography. B Heart J 29:512–519
Eckberg DL, White CW, Kioschos JM, Abboud FM (1974) Mechanisms mediating bradycardia during coronary arteriography. J Clin Invest 54:1455–1461
Eie H, Grendahl H, Nordvik A, Muëller C (1972) Electrocardiographic changes during selective coronary angiography. A comparison between Urografin 60% and Isopaque 2% without calcium ions. Acta Radiol [Diagn] 12:554–560
Ferńandez F, Scebat L, Lenègre J (1970) Electrocardiographic study of left intraventricular hemiblock in man during selective coronary arteriography. Am J Cardiol: 26:1–5
Friesinger GC, Schaeffer J, Criley M, Gaertner RA, Ross RS (1965) Hemodynamic consequences of the injection of radiopaque material. Circulation 31:730–790
Frink RJ, Merrick B, Lowe HM (1975) Mechanism of the bradycardia during coronary angiography. Am J Cardiol 35:17–22
Gensini GG, Dulbre J, Huntington PP, Kelly AE (1971) Left ventricular end-diastolic pressure before and after coronary arteriography: The value of coronary arteriography as a stress test. Am J Cardiol 27, 453–459
Gensini GG, DiGiori S (1964) Myocardial toxicity of contrast agents used in angiography. Radiology 82:24–34
Gootman N, Rudolph AM, Buckley NM (1980) Effects of angiographic contrast media on cardiac function. Am J Cardiol 25:59–65
Grendahl H, Eie H, Nordvik A, Müller C (1972) Electrocardiographic changes during selective coronary angiography. Acta Med Scand 191:493–500
Guzman SV, West JW (1969) Cardiac effects of intracoronary arterial injections of various roentgenographic contrast media. Am Heart J 38:597–607
Higgins CB, Schmidt W (1978) Direct and reflex myocardial effects of intracoronary administered contrast materials in the anesthetized and conscious dog. Comparison of standard and newer contrast material s. Invest Radiol 13:205–216
Hildner FJ, Scherlag B, Samet P (1971) Evaluation of Renografin M-76 as a contrast agent for angiocardiography. Radiology 100:329–334
Kaftori JK, Paulin S (1974) The effect of pH on the toxicity of Diatrizoate in selective coronary arteriography. An experimental study in dogs. Invest Radiol 9:351–355
Kaude JV, Lunderquist A, Persson A, Arnman K (1974) Selective coronary arteriography with Iodamide. A comparison of myocardial toxicity of two contrast media. Angiology 25:449–456
Kober G, Hopf R, Becker HJ, Kaltenbach M (1975) Wirkung und Nebenwirkungen der Kontrastmittel Urografin 76, Telebrix 300 und Telebrix 380 bei der selektiven Koronarangiographie des Menschen. Herz/Kreisl 7: 231–235
Lang J, Lasser LE (1975) Inhibition of adenosine triphosphatase and carbonic anhydrase by contrast media. Invest Radiol 10:314–316
Lehan PH, Harman A, Oldewurtel HA (1963) Myocardial water shifts induced by coronary arteriography (abstr). J Clin Invest 42:950
MacAlpin RN, Weidner WA, Kaltus AA, Hanafee WN (1966) Electrocardigraphic changes during selective coronary cineangiography. Circulation 34:627–637
Maytin O, Castillo C, Castellanos A Jr (1970) The genesis of QRS changes produced by selective coronary arteriography. Circulation 41:247–255
Nakhjavan FK, Smith AM, Dratch MB, Goldberg H (1974) His bundle electrogram during coronary arteriography in man: Studies at spontaneous and constant heart rates. J Electrocardiol 7:101–107
Neuerburg-Heusler D, Zeitler E, Blümchen G (1975) Das Koronarangiographie-Elektrokardiogramm und seine Aussagefähigkeit. Herz Kreisl 7:285–296
Paulin S, Adams DF (1971) Increased ventricular fibrillation during coronary arteriography with a new contrast medium preparation. Radiology 101:45–49
Reynolds G (1953) The electrocardiogram during angiocardiography. AJR 113:567–571
Smith RF, Hawthorne JW, Sanders CA (1967) Vectorcardiographic changes during intracoronary injections. Circulation 36:63–76
Snyder CF, Formanek A, Frech RS, Amplatz K: The role of sodium in promoting ventricular arrhythmia during selective coronary arteriography AJR 113:567
Talbert JL, Joyce EE, Sabiston DC Jr (1959) The effect of intra-arterial injection of radiopaque contrast media on coronary blood flow. Surgery 46:400–406
Trägårdh B, Bove AA, Lynch PR (1974) Cardiac conduction abnormalities during coronary arteriography in dogs: Reduced effects of a new contrast medium. Invest Radiol 9:340–345
Trägårdh B, Bove AA, Lynch PR (1976) Mechanism of production of cardiac conduction abnormalities due to coronary arteriography in dogs. Invest Radiol 11:563–568
Trägårdh B, Lynch PR, Vinciguerra I (1976) Cardiac function during coronary arteriography with calcium enriched diatrizoate and metrizamide. Invest Radiol 11:569–576
White CW, Eckberg DL, Abboud FM (1972) Influence of contrast media on the sinus node (abstr 149). Circulation (Suppl 2) 45/46:38
White CW, Eckberg DL, Koschos JM, Abboud FM (1973) A study of coronary artery reflexes in man (abstr 253). Circulation (Suppl 4) 7/8:65
White CW, Eckberg DL, Inasaka T, Abboud FM (1976) Effects of angiographic contrast media on sino-atrial nodal function. Cardiovasc Res 10:214–223
Wien AE (1979) Elektrokardiographische Veränderungen während selektiver Koronarangiographie. Inauguraldissertation Erlangen FRG
Weikl A (1981) Iopamidol in coronarografia. Radiol Med 67:Suppl 1, 398–401
Weikl A, Drust OE, Lang E (1975) Komplikationen der selektiven Koronarangiographie in Abhängigkeit von verwendeten Kontrastmitteln. ROEFO 123, 218–222
Weikl A, Spitzer W, Durst OE, Lang E (1980) Kardiale Nebenwirkungen von Hexabrix bei der Koronarangiographie. Krankenhausarzt 53:541–548
Zipfel J, Baller D, Blanke H, Jonas W, Karsch KR, Rentrop P, Hellige G (1980) Die Reduktion der kardialen Nebenwirkungen ionischer Kontrastmittel bei der Koronarangiographie durch Kalziumzusatz. Klinische Studie. Z Kardiol 69:406–413
Petetier A (1981) Congresso Nazionale Italiana di Radiologia Medica, Naples, p 250
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Weikl, A., Hubmann, M. A survey of contrast media used in coronary angiography. Cardiovasc Intervent Radiol 5, 202–210 (1982). https://doi.org/10.1007/BF02552311
Issue Date:
DOI: https://doi.org/10.1007/BF02552311