Electrical admittance cuff for non-invasive and simultaneous measurement of haematocrit, arterial pressure and elasticity using volume-oscillometric method

  • Blood Pressure
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

An improved technique based on the electrical admittance cuff was designed for the non-invasive measurement of haematocrit (Hct), together with blood pressure (BP) and arterial elasticity represented as volume elastic modulus (Ev), in human fingers. This device is made of a rigid annular chamber installed with a surrounding thin-walled tube (cuff), which is filled with electrolyte solution. A tetrapolar method is used to detect the admittance signals, both in the solution and in a finger segment placed through the cuff. With this device, it is theoretically shown that the resistivity of blood flowing into the segment is equal to that of the solution multiplied by the ratio of the admittance variation in the solution to that in the segment. Thus, the blood resistivity and therefore Hct can be non-invasively determined from the electrolyte resistivity and these two admittance variations. On the other hand, BP and Ev are also simultaneously measured from the admittance signals following the gradual change of the chamber pressure based on the volume-oscillometric method. Experiments were successfully made in 14 subjects, showing that the indirect Hct values agreed well with the direct values obtained from sampled blood and that this simle technique was significant for the non-invasive ad simultaneous measurement of these physiological variables.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cobbold, R. S. C. (1974): ‘Transducer for biomedical measurement; priciple and applications’ (John Wiley & Sons) p. 486

  • Dinnar, U. (1981): ‘Cardiovascular fluid dynamics’ (CRC Press Inc., Boca Raton, Florida) p. 252

    MATH  Google Scholar 

  • Fleming, J. S., Hames, T. K., andSmallwood, J. (1986): ‘Comparison of volume changes in the forearm assessed by impedance and water-displacement plethysmography,”Med. Biol. Eng. Comput.,24, pp. 375–378

    Article  Google Scholar 

  • Fricke, H. (1931): ‘The electric conductivity and capacity of disperse systems,”Phys.,1, pp. 106–115

    Article  Google Scholar 

  • Geddes, L. A., andSadler, C. (1973): ‘The specific resistance of blood at body temperature,”Med. Biol. Eng.,11, pp. 336–339

    Article  Google Scholar 

  • Hill, D. W., andThompson, F. D. (1975): ‘The effect of hematocrit on the resistivity of human blood at 37°C and 100 KHz,”Med. Biol. Eng.,13, pp. 182–186

    Article  Google Scholar 

  • Hill, D. W., andHope, C. E. (1976): ‘Computer technique in blood flow measurement’inWoodcock, J. (Ed.): ‘Clinical blood flow measurement’ (Sector Publishing, London) pp. 169–176

    Google Scholar 

  • Hill, D. W., andMohapatra, S. N. (1977): ‘The current status of electrical impedance techniques for the monitoring of cardiac output and limb blood flow,”inHill, D. W., andWatson, B. W. (Eds.): ‘IEE Medical Electronics monograph’ (Peter Peregrinus, UK) pp. 58–105

    Google Scholar 

  • Ito, H., Yamakoshi, K., andTogawa, T. (1976): ‘Transthoracic admittance plethysmography for measuring cardiac out-put,’J. Appl. Physiol.,40, pp. 451–454

    Google Scholar 

  • Kawarada, A., Shimazu, H., Yamakoshi, K., andKamiya, A. (1986): ‘Noninvasive automatic measurement of arterial elasticity in human fingers and rabbit forelegs using photoelectric plethysmography,”Med. Biol. Eng. Comput.,24, pp. 591–596

    Article  Google Scholar 

  • Kawarada, A., Shimazu, H., Ito, H., andYamakoshi, K. (1988): ‘Noninvasive measurement of arterial elasticity in various human limbs,’-ibid.,26, pp. 641–646

    Article  Google Scholar 

  • Kubicek, W. G., Witsoe, D. A., Patterson, R. P., andFrom, A. H. L. (1971): ‘Development and evaluation of an impedance cardiographic system to measure cardiac output and other cardiac parameters.’ National Aeronautical Space Administration Manned Spacecraft Center, Houston, Texas, Final Program Report, Contract NAS9-4500, pp. 15–19

  • McGovern, J. J., Jones, A. R., andSteinberg, A. G. (1955): ‘The hematocrit of capillary blood,”New. Eng. J. Med.,253, pp. 308–312

    Article  Google Scholar 

  • Mohapatora, S. N., andArenson, H. M. (1979): ‘The measurement of peripheral blood flow by the electrical impedance technique,”J. Med. Eng. Tech.,3, pp. 132–137

    Article  Google Scholar 

  • Nyboer, J. (1950): ‘Electrical impedance plethysmography; a physical and physiologic approach to peripheral vascular study,”Circ.,2, pp. 811–821

    Google Scholar 

  • Nyboer, J. (1970): ‘Electrical impedance plethysmography’ (C. C. Thomas, Springfield, Illinois) 2nd edn.

    Google Scholar 

  • Schraibman, I. G., Mott, D., Naylor, G. P., andCharlesworth, D. (1975): ‘Comparison of impedance and strain gauge plethysmography in the measurement of blood flow in the lower limb,”Br. J. Surg.,62, pp. 909–912

    Google Scholar 

  • Schwan, H. P. (1955): ‘Electrical properties of body tissue and impedance plethysmography,”IRE Trans. Bio-Med. Eng.,3, pp. 32–46

    Article  Google Scholar 

  • Shimazu, H., Yamakoshi, K., Togawa, T., Fukuoka, M., andIto, H. (1982): ‘Evaluation of the parallel conductor theory for measuring human limb blood flow by admittance plethysmography,”IEEE Trans.,BME-29, pp. 1–7

    Google Scholar 

  • Shimazu, H., Yamakoshi, K., andKamiya, A. (1986a): ‘Noninvasive measurement of the volume elastic modulus in finger arteries using photoelectric plethysmography,”-ibid.,BME-33, pp. 795–798

    Google Scholar 

  • Shimazu, H., Ito, H., Kobayashi, H., andYamakoshi, K. (1986b): ‘New idea to measure diastolic arterial pressure by the volume-oscillometric method in human fingers,”Med. Biol. Eng. Comput.,24, pp. 549–554

    Article  Google Scholar 

  • Shimazu, H., Kobayashi, H., Ito, H., andYamakoshi, K. (1987): ‘Indirect measurement of the systolic, mean and diastolic arterial pressure in the forearms and ankles of babies and children by the volume-oscillometric method,”J. Clin. Eng.,12, pp. 297–303

    Google Scholar 

  • Shimazu, H., Kawarada, A., Ito, H., andYamakoshi, K. (1989): ‘Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries,”Med. Biol. Eng. Comput.,27, 477–483

    Article  Google Scholar 

  • Woodcock, J. P. (1975): ‘Theory and practice of blood flow measurement’ (Butterworths & Co. Ltd., London, UK) 1st edn., p. 274

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Togawa, T., andIto, H. (1978): ‘Admittance plethysmography for accurate measurement of human limb blood flow,”Amer. J. Physiol.,235, pp. H821-H829

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Bukhari, A. R. S., Togawa, T., andIto, H. (1979): ‘Clinical evaluation of an electrical admittance blood flow monitor,”J. Clin. Eng.,4, pp. 341–346

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Togawa, T., Fukuoka, M., andIto, H. (1980): ‘Noninvasive measurement of hematocrit by electrical admittance plethysmography technique,”IEEE Trans.,BME-27, pp. 156–161

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Shibata, M., andKamiya, A. (1982a): ‘New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part I Model experiment,”Med. Biol. Eng. Comput.,20, pp. 307–313

    Article  Google Scholar 

  • Yamakoshi, K., Shimazu, H., Shibata, M., andKamiya, A. (1982b): ‘New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part II Correlation study,”Med. Biol. Eng. Comput.,20, pp. 314–318

    Article  Google Scholar 

  • Yamakoshi, K., andKamiya, A. (1987): ‘Noninvasive measurement of arterial blood pressure and elastic properties using photoelectric plethysmography technique,”Med. Progress Technol.,12, pp. 123–143

    Google Scholar 

  • Yamakoshi, K., Rolfe, P., andMurphy, C. (1988): ‘Current developments in non-invasive measurement of arterial blood pressure,”J. Biomed. Eng.,10, pp. 130–137

    Google Scholar 

  • Yamakoshi, K. (1991): ‘Non-invasive techniques for ambulatory blood pressure monitoring and simultaneous cardiovascular measurements,”J. Ambul. Monit.,4, pp. 123–143

    Google Scholar 

  • Yamamoto, Y., Yamamoto, T., andÖberg, P. Å. (1992): ‘Impedance plethysmography for blood flow measurements in human limbs. Part II Influence of limb cross-sectional area,’Med. Biol. Eng. Comput.,30, pp. 518–524

    Article  Google Scholar 

  • Young, D. G. Jr., Cox, R. H., Stoner, E. K., andErdman, W. J. (1967a): ‘Evaluation of quantitative impedance plethysmography for continuous blood flow measurement, I. Electrode systems,”Amer. J. Phys. Med.,46, 1261–1275

    Google Scholar 

  • Young, D. G. Jr., Cox, R. H., Stoner, E. K., andErdman, W. J. (1967b): ‘Evaluation of quantitative impedance plethysmography for continuous blood flow mesurement, III. Blood flow determination in vivo,’-ibid,46, 1450–1457

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yamakoshi, K., Tanaka, S. & Shimazu, H. Electrical admittance cuff for non-invasive and simultaneous measurement of haematocrit, arterial pressure and elasticity using volume-oscillometric method. Med. Biol. Eng. Comput. 32 (Suppl 1), S99–S107 (1994). https://doi.org/10.1007/BF02523335

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02523335

Keywords

Navigation