Adaptive filters for analysis of intra-cardiac signals

  • Electrocardiography
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Implantable cardioverters and defibrillators must discriminate malignant ventricular arrhythmias from other supraventricular tachycardias. Electrogram signals are sensed by a single floating endocardial catheter with multiple sensors. The sensors acquire composite atrial and ventricular complexes from atrial and ventricular chambers. Two adaptive filters are utilised to discriminate atrial signals from ventricular signals. The adaptive impulse correlated filter utilises an impulse sequence correlated with the ventricular depolarisations in order to filter the composite signal. This filter should be useful in the analysis of atrial arrhythmias. The adaptive series feedback filter utilises two back-to-back coupled filters to simultaneously extract ventricular depolarisations from one input channel and atrial depolarisations from another channel. This filter should be useful in the analysis of ventricular arrhythmias. Theoretical analysis of the adaptation capabilities of these filters and criteria for convergence are presented. Experimental electrogram recordings are analysed to demonstrate the performance of the two filters. Computational simplicity of these filters makes them particularly suitable for programmable implantable devices.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Davies, D. W., Wainwright, R. J., Tooley, M. A., Lloyd, D., Nathan, A. W., Spurrell, R. A. J., andCamm, A. J. (1986): ‘Detection of pathological tachycardia by analysis of electrogram morphology’,Pace,9, pp. 200–208

    Google Scholar 

  • Laguna, P., Jane, R., Meste, O., Poon, P., Caminal, P., Rix, H., andThakor, N. V. (1992): ‘Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques’,IEEE Trans.,BME-39, pp. 1032–1044

    Google Scholar 

  • Lin, D., DiCarlo, L. A., andJenkins, J. M. (1988): ‘Identification of ventricular tachycardia using intracavitary electrograms: analysis of time and frequency domain patterns’,Pace,11, pp. 241–249

    Google Scholar 

  • Mirowski, M., Mower, M. M., andReid, P. R. (1980): ‘The automatic implantable defibrillator’,Amer. Heart J.,100, pp. 1089–1092

    Article  Google Scholar 

  • Pan, J., andTompkins, W. J. (1985): ‘A real-time QRS detection algorithm’,IEEE Trans.,BME-32, pp. 230–236

    Google Scholar 

  • Ripley, K. R., Bump, T. B., andArzbaecher, R. C. (1989): ‘Evaluation of techniques for recognition of ventricular arrhythmias by implantable devices’,IEEE Trans.,BME-36, pp. 618–624

    Google Scholar 

  • Ropella, K. M., Sahakian, A. V., Baerman, J. M., andSwiryn, S. (1990): ‘Differentiation of ventricular tachyarrhythmias’,Circ.,82, pp. 2035–2043

    Google Scholar 

  • Shoupu, C., Thakor, N. V., andMower, M. M. (1987): ‘Ventricular fibrillation detection by regression test of autocorrelation function’,Med. Biol. Eng. Comput.,25, pp. 241–249

    Article  Google Scholar 

  • Slocum, J., Sahakian, A., andSwiryn, S. (1988): ‘Computer discrimination of atrial fibrillation and regular atrial rhythms from intra-atrial electrograms’,Pace,11, pp. 610–621

    Google Scholar 

  • Thakor, N. V., Yi-Sheng, Z., andPan, K. (1990): ‘Ventricular tachycardia and fibrillation detection by a sequential hypothesis testing algorithm’,IEEE Trans.,BME-37, pp. 837–843

    Google Scholar 

  • Thakor, N. V., Xin-rong, G., andNatarajan, N. (1991): ‘Adaptive filters for rhythm discrimination: a floating endocardial lead’,Proc. Comput. Cardiol., Venice, Italy, 23–26 September (IEEE Comput. Soc. Press), pp. 193–196

  • Thakor, N. V., andYi-Sheng, Z. (1991): ‘Some applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection’,IEEE Trans.,BME-38, pp. 785–794

    Google Scholar 

  • Tomaselli, G. P., Nielsen, A. P., Finke, W. L., Singupta, L., Clark, J. C., andGriffin, J. C. (1988): ‘Morphological differences of the endocardial electrogram in beats of sinus and ventricular arrhythmias,’Pace,11, pp. 254–262

    Google Scholar 

  • Widrow, B., andStearns, S. S. (1985): ‘Adaptive signal processing’, (Prentice Hall, New Jersey)

    MATH  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thakor, N.V. Adaptive filters for analysis of intra-cardiac signals. Med. Biol. Eng. Comput. 32 (Suppl 1), S19–S24 (1994). https://doi.org/10.1007/BF02523323

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02523323

Keywords

Navigation