Pulsewidth optimisation for transformer-coupled transcutaneous current pulse generation

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A general theoretical approach for the determination of the optimum pulsewidth used for TENS/EMS/FES is presented. Analysis based on the interaction between a stepup transformer-coupled nerve stimulator and an electrode-tissue load modelled as a simple lossy capacitive load results in excellent agreement between the predicted and measured performance. The analysis shows that, by adjusting the pulsewidth (PW) of a push-pull symmetric square waveform such that PW=4.5τ, the total charge delivered to the tissue load can be minimised without impacting the efficiency of the nerve stimulation. Additionally, by minimising the charge exchange supported portion of the current pulse, which is primarily responsible for the pH shift and subsequent tissue burning with longterm use, the latter can be reduced to an acceptable level.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • AAMI (1986): ‘American national standard for transcutaneous electrical nerve stimulators.’Assoc. Advanc. Med. Instrum., 3330 Washington Blvd., Suite 400, Arlington, VA 22201-4598, USA

  • Bing-He, Z., Baratta, R. andSolomonow, M. (1987): ‘Manipulation of muscle force with various firing rate and recruitment control strategies,’IEEE Trans.,BME-34, pp. 123–130.

    Google Scholar 

  • Flanagan, W. M. (1986): ‘Handbook of transformer applications’ (McGraw-Hill, New York) pp. 1.5–1.6

    Google Scholar 

  • Geddes, L. A. andBourland, J. D. (1985): ‘The strength-duration curve,’IEEE Trans.,BME-32, pp. 301–310

    Google Scholar 

  • Malezic, M., Stanic, U. andKljajic, M. (1984): ‘Multichannel electrical stimulation of gait in motor disabled patients,’Orthopedics,7, pp. 1187–1195

    Google Scholar 

  • Milner-Brown, H., Stein, R. B. andYemm, R. (1973): ‘The orderly recruitment of human motor units during voluntary isometric contraction,’J. Physiol. Lond.,230, pp. 339–370.

    Google Scholar 

  • Petrofsky, J. S. andSmith, J. (1991): ‘A combined computer-controlled walking and exercise system,’J. Clin. Eng.,16, pp. 223–235

    Google Scholar 

  • Ragheb, T. andGeddes, L. A. (1990): ‘Electrical properties of metallic electrodes,’IEEE Trans.,BME-37, pp. 323–329.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. T. Kolen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kolen, P.T. Pulsewidth optimisation for transformer-coupled transcutaneous current pulse generation. Med. Biol. Eng. Comput. 36, 471–474 (1998). https://doi.org/10.1007/BF02523216

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02523216

Keywords

Navigation